Literature DB >> 16914218

Development and evaluation of a Taqman duplex real-time PCR quantification method for reliable enumeration of Legionella pneumophila in water samples.

Jonas Behets1, Priscilla Declerck, Yasmine Delaedt, Bart Creemers, Frans Ollevier.   

Abstract

This study describes the development and evaluation of a specific Legionella pneumophila Taqman duplex real-time PCR (qPCR) for fast and reliable quantification of this human pathogen in suspected man-made water systems. The qPCR assay was 100% specific for all L. pneumophila serogroups 1-15 with a sensitivity of 60 genome units/l and an amplification efficiency of 98%. Amplification inhibitors were detected via an exogenous internal positive control, which was amplified simultaneously with L. pneumophila DNA using its own primer and probe set. Mean recovery rates of the qPCR assay for tap water and cooling circuit water, spiked with a known number L. pneumophila bacteria, were 93.0% and 56.3%, respectively. Additionally, by using the Ultraclean Soil DNA isolation kit, we were able to remove amplification inhibitors ubiquitously present in cooling water. The practical value of our qPCR assay was evaluated through analysis of 30 water samples from showers, taps, eyewash stations, fire sprinklers and recirculation loops with qPCR and traditional culture. In conclusion, the described L. pneumophila Taqman duplex real-time assay proved to be specific, sensitive and reproducible. This makes it a promising method complementing the current time-consuming culture standard method.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16914218     DOI: 10.1016/j.mimet.2006.07.002

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  18 in total

1.  PCR method for the rapid detection and discrimination of Legionella spp. based on the amplification of pcs, pmtA, and 16S rRNA genes.

Authors:  Monika Janczarek; Marta Palusińska-Szysz
Journal:  J Appl Genet       Date:  2015-09-30       Impact factor: 3.240

2.  Integrated real-time PCR for detection and monitoring of Legionella pneumophila in water systems.

Authors:  Diaraf Farba Yaradou; Sylvie Hallier-Soulier; Sophie Moreau; Florence Poty; Yves Hillion; Monique Reyrolle; Janine André; Gabriel Festoc; Karine Delabre; François Vandenesch; Jerome Etienne; Sophie Jarraud
Journal:  Appl Environ Microbiol       Date:  2006-12-28       Impact factor: 4.792

3.  On-filter direct amplification of Legionella pneumophila for rapid assessment of its abundance and viability.

Authors:  Farag A Samhan; Tiffany M Stedtfeld; Hassan Waseem; Maggie R Williams; Robert D Stedtfeld; Syed A Hashsham
Journal:  Water Res       Date:  2017-05-13       Impact factor: 11.236

4.  Assessment of Legionella pneumophila in recreational spring water with quantitative PCR (Taqman) assay.

Authors:  Shu-Min Shen; Ming-Yuan Chou; Bing-Mu Hsu; Wen-Tsai Ji; Tsui-Kang Hsu; Hsiu-Feng Tsai; Yu-Li Huang; Yi-Chou Chiu; Erl-Shyh Kao; Po-Min Kao; Cheng-Wei Fan
Journal:  Pathog Glob Health       Date:  2015-07-16       Impact factor: 2.894

5.  Error estimation in environmental DNA targets quantification due to PCR efficiencies differences between real samples and standards.

Authors:  Leonardo Martín Pérez; Mariana Fittipaldi; Bárbara Adrados; Jordi Morató; Francesc Codony
Journal:  Folia Microbiol (Praha)       Date:  2013-05-07       Impact factor: 2.099

6.  Specific real-time PCR for simultaneous detection and identification of Legionella pneumophila serogroup 1 in water and clinical samples.

Authors:  N Mérault; C Rusniok; S Jarraud; L Gomez-Valero; C Cazalet; M Marin; E Brachet; P Aegerter; J L Gaillard; J Etienne; J L Herrmann; C Lawrence; C Buchrieser
Journal:  Appl Environ Microbiol       Date:  2010-12-30       Impact factor: 4.792

Review 7.  Methodological approaches for monitoring opportunistic pathogens in premise plumbing: A review.

Authors:  Hong Wang; Emilie Bédard; Michèle Prévost; Anne K Camper; Vincent R Hill; Amy Pruden
Journal:  Water Res       Date:  2017-03-25       Impact factor: 11.236

8.  Replication of Legionella pneumophila in floating biofilms.

Authors:  Priscilla Declerck; Jonas Behets; Vincent van Hoef; Frans Ollevier
Journal:  Curr Microbiol       Date:  2007-08-23       Impact factor: 2.188

9.  A PCR-based method for monitoring Legionella pneumophila in water samples detects viable but noncultivable legionellae that can recover their cultivability.

Authors:  Eric Dusserre; Christophe Ginevra; Sylvie Hallier-Soulier; François Vandenesch; Gabriel Festoc; Jerome Etienne; Sophie Jarraud; Maëlle Molmeret
Journal:  Appl Environ Microbiol       Date:  2008-05-30       Impact factor: 4.792

10.  Viability PCR, a culture-independent method for rapid and selective quantification of viable Legionella pneumophila cells in environmental water samples.

Authors:  Pilar Delgado-Viscogliosi; Lydie Solignac; Jean-Marie Delattre
Journal:  Appl Environ Microbiol       Date:  2009-04-10       Impact factor: 4.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.