Literature DB >> 16913547

Perinatal outcome associated with sonographically detected globular placenta.

Luissa Fisteag-Kiprono1, Ran Neiger, Jiri D Sonek, Christopher S Croom, David S McKenna, Gary Ventolini.   

Abstract

OBJECTIVE: To evaluate the association between the sonographic appearance of globular placenta and perinatal outcome. STUDY
DESIGN: We prospectively followed the pregnancy course and perinatal outcome in women with globular placentas (hyperechoic, thick and highly vascular placentas with edges that lack the typical "tapering" appearance) during routine sonographic study.
RESULTS: Fourteen women were included. In 7 women the globular appearance of the placenta normalized spontaneously, and perinatal outcome was good. The other 7 experienced poor perinatal outcomes. There were no significant differences between the 2 groups. Among pregnancies in which the globular placental appearance persisted, 3 resulted in fetal demise; 3 women had severe intrauterine growth restriction and oligohydramnios and underwent cesarean deliveries at 26, 27 and 31 weeks, respectively; and 1 patient had premature preterm rupture of membranes and underwent a cesarean delivery due to placental abruption.
CONCLUSION: In half the pregnancies complicated by the sonographic appearance of a globular placenta, this shape spontaneously normalized, and the perinatal outcome was normal. However, when the globular appearance of the placenta persisted, the condition was associated with a poor perinatal outcome. Pregnancies complicated by a globular placenta should be followed closely.

Entities:  

Mesh:

Year:  2006        PMID: 16913547

Source DB:  PubMed          Journal:  J Reprod Med        ISSN: 0024-7758            Impact factor:   0.142


  3 in total

1.  In vivo placental MRI shape and textural features predict fetal growth restriction and postnatal outcome.

Authors:  Sonia Dahdouh; Nickie Andescavage; Sayali Yewale; Alexa Yarish; Diane Lanham; Dorothy Bulas; Adre J du Plessis; Catherine Limperopoulos
Journal:  J Magn Reson Imaging       Date:  2017-07-22       Impact factor: 4.813

2.  Biochemical tests of placental function versus ultrasound assessment of fetal size for stillbirth and small-for-gestational-age infants.

Authors:  Alexander Ep Heazell; Dexter Jl Hayes; Melissa Whitworth; Yemisi Takwoingi; Susan E Bayliss; Clare Davenport
Journal:  Cochrane Database Syst Rev       Date:  2019-05-14

3.  MR Imaging of Fetuses to Evaluate Placental Insufficiency.

Authors:  Yoshimitsu Ohgiya; Hiroshi Nobusawa; Noritaka Seino; Osamu Miyagami; Naomi Yagi; Sasamori Hiroto; Jiro Munechika; Masanori Hirose; Nobuyuki Takeyama; Nobuyuki Ohike; Ryu Matsuoka; Akihiko Sekizawa; Takehiko Gokan
Journal:  Magn Reson Med Sci       Date:  2015-11-25       Impact factor: 2.471

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.