Literature DB >> 16912947

Frequency of permanent pacemaker or implantable cardioverter-defibrillator infection in patients with gram-negative bacteremia.

Daniel Z Uslan1, Muhammad R Sohail, Paul A Friedman, David L Hayes, Walter R Wilson, James M Steckelberg, Larry M Baddour.   

Abstract

BACKGROUND: Despite the frequent occurrence of bacteremia due to gram-negative organisms in patients with underlying permanent pacemakers (PPMs) or implantable cardioverter defibrillators (ICDs), the outcome and treatment of these patients has received scant attention. In patients with PPMs or ICDs who have Staphylococcus aureus bacteremia, 45% have PPM/ICD infection.
METHODS: We conducted a retrospective cohort study over a 7-year period to assess the clinical features and frequency of PPM/ICD infection in patients with gram-negative bacteremia, as well as the incidence of relapse in patients for whom the device was not removed.
RESULTS: Forty-nine patients were included in the study; 3 (6%) had either definite (2 patients) or possible (1 patient) PPM/ICD infection. Both patients with definite PPM/ICD infection had clear infection of the generator pocket. None of the other patients with alternate sources of bacteremia developed PPM/ICD infection. Thirty-four patients with retained PPM/ICD were observed for >12 weeks (median time, 759 days), and 2 (6%) developed relapsing bacteremia, although they each had alternative sources of relapse.
CONCLUSIONS: In sharp contrast to S. aureus infection, PPM/ICD infection in patients with gram-negative bacteremia was rare, and no patients appeared to have secondary PPM/ICD infection due to hematogenous seeding of the system. Despite infrequent system removal in these patients, relapsing bacteremia among patients who survived initial bacteremia was rarely seen. If secondary PPM/ICD infection occurs in patients with gram-negative bacteremia, it is either uncommon or it is cured with antimicrobial therapy despite device retention.

Entities:  

Mesh:

Year:  2006        PMID: 16912947     DOI: 10.1086/506942

Source DB:  PubMed          Journal:  Clin Infect Dis        ISSN: 1058-4838            Impact factor:   9.079


  16 in total

1.  Management of infections involving implanted cardiac electrophysiologic devices.

Authors:  Frédéric L Paulin; Lorne J Gula; Raymond Yee; Allan C Skanes; George J Klein; Andrew D Krahn
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-09

2.  Incubation alone is adequate as a culturing technique for cardiac rhythm management devices.

Authors:  George M Viola; Mohammad D Mansouri; Nadim Nasir; Rabih O Darouiche
Journal:  J Clin Microbiol       Date:  2009-10-21       Impact factor: 5.948

Review 3.  [Hypersensitivity reactions to implantable cardiac pacemakers and defibrillators].

Authors:  B Kreft
Journal:  Hautarzt       Date:  2016-05       Impact factor: 0.751

4.  Sonication of explanted cardiac rhythm management devices for the diagnosis of pocket infections and asymptomatic bacterial colonization.

Authors:  Pamela K Mason; John P Dimarco; John D Ferguson; Srijoy Mahapatra; J Michael Mangrum; Kenneth C Bilchick; J Randall Moorman; Douglas E Lake; James D Bergin
Journal:  Pacing Clin Electrophysiol       Date:  2011-02       Impact factor: 1.976

5.  Management of Cardiac Electronic Device Infections: Challenges and Outcomes.

Authors:  Rikke Esberg Kirkfeldt; Jens Brock Johansen; Jens Cosedis Nielsen
Journal:  Arrhythm Electrophysiol Rev       Date:  2016

6.  [Device related infections. How to identify and how to treat].

Authors:  Christoph Stellbrink; Bert Hansky
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-09

7.  Cardiac implantable electronic device infections: facts, current practice, and the unanswered questions.

Authors:  Khaldoun G Tarakji; Bruce L Wilkoff
Journal:  Curr Infect Dis Rep       Date:  2014-09       Impact factor: 3.725

8.  Clinical manifestations of lead-dependent infective endocarditis: analysis of 414 cases.

Authors:  A Polewczyk; M Janion; R Podlaski; A Kutarski
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2014-05-03       Impact factor: 3.267

9.  Genetic identification and risk factor analysis of asymptomatic bacterial colonization on cardiovascular implantable electronic devices.

Authors:  Xian-Ming Chu; Bing Li; Yi An; Xue-Bin Li; Ji-Hong Guo
Journal:  Biomed Res Int       Date:  2014-11-02       Impact factor: 3.411

10.  Identification of bacteriology and risk factor analysis of asymptomatic bacterial colonization in pacemaker replacement patients.

Authors:  Xian-Ming Chu; Hua Yu; Xue-Xia Sun; Yi An; Bing Li; Xue-Bin Li
Journal:  PLoS One       Date:  2015-03-13       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.