Ahalya Subramanian1, Shahina Pardhan. 1. Department of Optometry and Visual Science, City University, London, UK. Ahalya.Subramanian.1@city.ac.uk
Abstract
PURPOSE: The purposes of this study are to establish the repeatability of the MNREAD acuity charts in a normal adult population and to determine the coefficient of repeatability for reading acuity, reading speed, and critical print size. The study also investigates how changing the working distance affects these parameters. METHODS: Thirty normal young adults (mean age, 23.3 years) participated. Test-retest repeatability was assessed at 40 cm over two sessions by the same examiner using MNREAD charts 1 and 2. Additional measurements were also carried out at 24 cm and 52 cm working distances. The distance and the version of the chart used were randomized. RESULTS: The coefficient of repeatability was found to be +/- 0.05 logarithm of the minimum angle of resolution (logMAR) for reading acuity, +/- 0.12 logMAR for critical print size, and +/- 8.6 words per minute for reading speed. Reading acuity and critical print size changed significantly with testing distance (p = 0.001). No changes were found in the reading speed at the different test distances (p = 0.27). CONCLUSIONS: The MNREAD acuity charts can be used reliably to measure reading acuity, reading speed, and critical print size in a normal adult population.
PURPOSE: The purposes of this study are to establish the repeatability of the MNREAD acuity charts in a normal adult population and to determine the coefficient of repeatability for reading acuity, reading speed, and critical print size. The study also investigates how changing the working distance affects these parameters. METHODS: Thirty normal young adults (mean age, 23.3 years) participated. Test-retest repeatability was assessed at 40 cm over two sessions by the same examiner using MNREAD charts 1 and 2. Additional measurements were also carried out at 24 cm and 52 cm working distances. The distance and the version of the chart used were randomized. RESULTS: The coefficient of repeatability was found to be +/- 0.05 logarithm of the minimum angle of resolution (logMAR) for reading acuity, +/- 0.12 logMAR for critical print size, and +/- 8.6 words per minute for reading speed. Reading acuity and critical print size changed significantly with testing distance (p = 0.001). No changes were found in the reading speed at the different test distances (p = 0.27). CONCLUSIONS: The MNREAD acuity charts can be used reliably to measure reading acuity, reading speed, and critical print size in a normal adult population.
Authors: Uri Polat; Clifton Schor; Jian-Liang Tong; Ativ Zomet; Maria Lev; Oren Yehezkel; Anna Sterkin; Dennis M Levi Journal: Sci Rep Date: 2012-02-23 Impact factor: 4.379
Authors: Aurélie Calabrèse; Long To; Yingchen He; Elizabeth Berkholtz; Paymon Rafian; Gordon E Legge Journal: J Vis Date: 2018-01-01 Impact factor: 2.240
Authors: Aurélie Calabrèse; Allen M Y Cheong; Sing-Hang Cheung; Yingchen He; MiYoung Kwon; J Stephen Mansfield; Ahalya Subramanian; Deyue Yu; Gordon E Legge Journal: Invest Ophthalmol Vis Sci Date: 2016-07-01 Impact factor: 4.799