Literature DB >> 16908773

Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial.

Jean Fajadet1, William Wijns, Gert-Jan Laarman, Karl-Heinz Kuck, John Ormiston, Thomas Münzel, Jeffrey J Popma, Peter J Fitzgerald, Raoul Bonan, Richard E Kuntz.   

Abstract

BACKGROUND: The use of the Endeavor stent might reduce restenosis and stent thrombosis at 9 months. METHODS AND
RESULTS: Patients (n = 1197) treated for single coronary artery stenosis were enrolled in a prospective, randomized, double-blind study and randomly assigned to receive the Endeavor zotarolimus-eluting phosphorylcholine polymer-coated stent (n = 598) or the same bare metal stent but without the drug or the polymer coating (n = 599). The 2 groups were well matched in baseline characteristics. Diabetes was present in 20.1% of patients; the mean reference vessel diameter was 2.75 mm; and the mean lesion length was 14.2 mm. The primary end point of target vessel failure at 9 months was reduced from 15.1% with the bare metal stent to 7.9% with the Endeavor (P = 0.0001), and the rate of major adverse cardiac events was reduced from 14.4% with the bare metal stent to 7.3% with the Endeavor (P = 0.0001). Target lesion revascularization was 4.6% with Endeavor compared with 11.8% with the bare metal stent (P = 0.0001). The rate of stent thrombosis was 0.5% with the Endeavor, which was not significantly different from 1.2% with the bare metal stent. In 531 patients submitted to angiographic follow-up, late loss was reduced from 1.03 +/- 0.58 to 0.61 +/- 0.46 (P < 0.001) in stent and from 0.72 +/- 0.61 to 0.36 +/- 0.46 (P < 0.001) in segment. The rate of in-segment restenosis was reduced from 35.0% to 13.2% with Endeavor (P < 0.0001). There was no excessive edge stenosis, aneurysm formation, or late acquired malapposition by intravascular ultrasound imaging. Differences in clinical outcome were maintained at 12 and 24 months (P < 0.0001).
CONCLUSIONS: Compared with bare metal stents, the Endeavor stent is safe and reduces the rates of clinical and angiographic restenosis at 9, 12, and 24 months.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16908773     DOI: 10.1161/CIRCULATIONAHA.105.591206

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  61 in total

1.  Drug-eluting stents in the elderly.

Authors:  Samip Vasaiwala; Daniel E Forman; Laura Mauri
Journal:  Curr Treat Options Cardiovasc Med       Date:  2010-01

2.  Drug-eluting stents.

Authors:  Xiaodong Ma; Tim Wu; Michael P Robich; Xingwei Wang; Hao Wu; Bryan Buchholz; Stephen McCarthy
Journal:  Int J Clin Exp Med       Date:  2010-07-15

3.  Efficacy of Endeavor zotarolimus-eluting stent implantation for the treatment of very late stent thrombosis with late-acquired incomplete stent apposition after sirolimus-eluting stent implantation.

Authors:  Yuki Kakefuda; Akira Sato; Hiroaki Watabe; Hideaki Aihara; Hidetaka Nishina; Yuichi Noguchi; Tomoya Hoshi; Kazutaka Aonuma
Journal:  Heart Vessels       Date:  2015-07-29       Impact factor: 2.037

4.  Revascularization treatment in patients with coronary artery disease.

Authors:  S G Foussas; G Z Tsiaousis
Journal:  Hippokratia       Date:  2008-01       Impact factor: 0.471

5.  In vitro study of dual drug-eluting stents with locally focused sirolimus and atorvastatin release.

Authors:  Svea Petersen; Janine Hussner; Thomas Reske; Niels Grabow; Volkmar Senz; Robert Begunk; Daniela Arbeiter; Heyo K Kroemer; Klaus-Peter Schmitz; Henriette E Meyer zu Schwabedissen; Katrin Sternberg
Journal:  J Mater Sci Mater Med       Date:  2013-07-12       Impact factor: 3.896

Review 6.  Strategies for postmarketing surveillance of drugs and devices in patients with ESRD undergoing dialysis.

Authors:  Moshe Vardi; Robert W Yeh; Charles A Herzog; Wolfgang C Winkelmayer; Soko Setoguchi; David M Charytan
Journal:  Clin J Am Soc Nephrol       Date:  2013-08-22       Impact factor: 8.237

7.  One-year clinical outcomes of BioMatrix™-Biolimus A9™ eluting stent: the e-BioMatrix multicenter post marketing surveillance registry in India.

Authors:  Ashwin B Mehta; Praveen Chandra; Jamshed Dalal; Prabhakar Shetty; Devang Desai; K Chocklingam; Jayesh Prajapati; Pramod Kumar; Vilas Magarkar; Apurva Vasawada; B K Goyal; Viveka Kumar; V Suryaprakash Rao; Ramesh Babu; Pritesh Parikh; Upendra Kaul; Aruna Patil; Tushar Mhetre; Hrishikesh Rangnekar
Journal:  Indian Heart J       Date:  2013-09-23

8.  Angiographic results of the cobalt chromium Vision and Mini-Vision stents.

Authors:  Jochen Wöhrle; Thorsten Nusser; Stephanie Hoffmann; Matthias Kochs
Journal:  Can J Cardiol       Date:  2009-10       Impact factor: 5.223

Review 9.  Delivery of large biopharmaceuticals from cardiovascular stents: a review.

Authors:  Hironobu Takahashi; Didier Letourneur; David W Grainger
Journal:  Biomacromolecules       Date:  2007-10-12       Impact factor: 6.988

10.  A first-in-man study of sirolimus-eluting, biodegradable polymer coated cobalt chromium stent in real life patients.

Authors:  Ashok Seth; Praveen Chandra; Nagendra S Chouhan; Ashok S Thakkar
Journal:  Indian Heart J       Date:  2012-07-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.