Literature DB >> 16908454

UV air cleaners and upper-room air ultraviolet germicidal irradiation for controlling airborne bacteria and fungal spores.

Elmira Kujundzic1, Fatimah Matalkah, Cody J Howard, Mark Hernandez, Shelly L Miller.   

Abstract

In-room air cleaners (ACs) and upper-room air ultraviolet germicidal irradiation (UVGI) are engineering control technologies that can help reduce the concentrations of airborne bacteria and fungal spores in the indoor environment. This study investigated six different types of ACs and quantified their ability to remove and/or inactivate airborne bacteria and fungal spores. Four of the air cleaners incorporated UV lamp(s) into their flow path. In addition, the efficacy of combining ACs with upper-room air UVGI was investigated. With the ventilation system providing zero or six air changes per hour, the air cleaners were tested separately or with the upper-room air UVGI system in operation in an 87-m3 test room. Active bacteria cells and fungal spores were aerosolized into the room such that their numbers and physiologic state were comparable both with and without air cleaning and upper-room air UVGI. In addition, the disinfection performance of a UV-C lamp internal to one of the ACs was evaluated by estimating the percentage of airborne bacteria cells and fungal spores captured on the air filter medium surface that were inactivated with UV exposure. Average airborne microbial clean air delivery rates (CADRm) varied between 26-981 m3 hr-1 depending on the AC, and between 1480-2370 m3 hr-1, when using air cleaners in combination with upper-room air UVGI. Culturing, direct microscopy, and optical particle counting revealed similar CADRm. The ACs performed similarly when challenged with three different microorganisms. Testing two of the ACs showed that no additional air cleaning was provided with the operation of an internal UV-C lamp; the internal UV-C lamps, however, inactivated 75% of fungal spores and 97% of bacteria cells captured in the air filter medium within 60 min.

Mesh:

Substances:

Year:  2006        PMID: 16908454     DOI: 10.1080/15459620600909799

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  16 in total

1.  Reopening Schools After a Novel Coronavirus Surge.

Authors:  Dan Li; Elizabeth Z Lin; Marie A Brault; Julie Paquette; Sten H Vermund; Krystal J Godri Pollitt
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

2.  A chemical free, nanotechnology-based method for airborne bacterial inactivation using engineered water nanostructures.

Authors:  Georgios Pyrgiotakis; James McDevitt; Andre Bordini; Edgar Diaz; Ramon Molina; Christa Watson; Glen Deloid; Steve Lenard; Natalie Fix; Yosuke Mizuyama; Toshiyuki Yamauchi; Joseph Brain; Philip Demokritou
Journal:  Environ Sci Nano       Date:  2014

3.  Mycobacteria inactivation using Engineered Water Nanostructures (EWNS).

Authors:  Georgios Pyrgiotakis; James McDevitt; Ya Gao; Alan Branco; Mary Eleftheriadou; Bernardo Lemos; Edward Nardell; Philip Demokritou
Journal:  Nanomedicine       Date:  2014-03-12       Impact factor: 5.307

Review 4.  Balancing incomplete COVID-19 evidence and local priorities: risk communication and stakeholder engagement strategies for school re-opening.

Authors:  Anna G Hoover; Wendy Heiger-Bernays; Sweta Ojha; Kelly G Pennell
Journal:  Rev Environ Health       Date:  2020-10-01       Impact factor: 3.458

5.  Viruses contained in droplets applied on warmed surface are rapidly inactivated.

Authors:  Swan Firquet; Sophie Beaujard; Pierre-Emmanuel Lobert; Famara Sané; Delphine Caloone; Daniel Izard; Didier Hober
Journal:  Microbes Environ       Date:  2014-12-03       Impact factor: 2.912

6.  The Study of an Ultraviolet Radiation Technique for Removal of the Indoor Air Volatile Organic Compounds and Bioaerosol.

Authors:  Chao-Yun Liu; Chao-Heng Tseng; Huang-Chin Wang; Chuan-Fa Dai; Yi-Hsuan Shih
Journal:  Int J Environ Res Public Health       Date:  2019-07-17       Impact factor: 3.390

7.  Home life: factors structuring the bacterial diversity found within and between homes.

Authors:  Robert R Dunn; Noah Fierer; Jessica B Henley; Jonathan W Leff; Holly L Menninger
Journal:  PLoS One       Date:  2013-05-22       Impact factor: 3.240

8.  An evaluation of the infection control potential of a UV clinical podiatry unit.

Authors:  Paul N Humphreys; Chris S Davies; Simon Rout
Journal:  J Foot Ankle Res       Date:  2014-02-28       Impact factor: 2.303

9.  Microwave assisted nanofibrous air filtration for disinfection of bioaerosols.

Authors:  Qi Zhang; Brian Damit; James Welch; Hyoungjun Park; Chang-Yu Wu; Wolfgang Sigmund
Journal:  J Aerosol Sci       Date:  2010-06-10       Impact factor: 3.433

Review 10.  The Role of Indoor Plants in air Purification and Human Health in the Context of COVID-19 Pandemic: A Proposal for a Novel Line of Inquiry.

Authors:  Rania El-Tanbouly; Ziad Hassan; Sarah El-Messeiry
Journal:  Front Mol Biosci       Date:  2021-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.