Joon-Sup Yeom1, Gyo Jun, Young Chang, Mi-Jin Sohn, Seungbum Yoo, Eunkyung Kim, Seung-Ho Ryu, Hee-Jung Kang, Young-A Kim, Sun-Young Ahn, Je-Eun Cha, Sung-Tae Youn, Jae-Won Park.
Abstract
The LG HIV Ag-Ab Plus, a new fourth generation diagnostic assay for HIV infection, was evaluated in comparison to the Enzygnost HIV Integral, an established fourth generation HIV assay. The LG assay showed 100% sensitivity with 109 samples with anti-HIV-1, anti-HIV-2 or anti-HIV-1 group O reactivity. It also detected correctly all 51 positives on three BBI performance panels, slightly outperforming the Enzygnost HIV Integral, which detected 50. The specificity of the LG HIV Ag-Ab Plus was 99.9% with 999 sera from healthy blood donors, which was slightly inferior to the performance of the Enzygnost HIV Integral, which had 100% specificity. The LG assay showed 100% specificity with 81 specimens with underlying diseases including hepatitis B, demonstrating a low risk of cross-reactivity with other infections. The reduction of the diagnostic window by the LG HIV Ag-Ab Plus, compared to a third generation HIV assay, was 6.3 days. The LG assay also showed sufficiently high intra-person and inter-person reproducibility. The overall performance of this new fourth generation HIV assay was adequate for screening and diagnosis of HIV infection.Entities:
Mesh:
Substances:
Year: 2006 PMID: 16908076 DOI: 10.1016/j.jviromet.2006.07.002