Abstract

Although various techniques are advocated to establish tibial rotational alignment during total knee arthroplasty, it is unknown which is most repeatable. We evaluated the precision and accuracy of five tibial rotational alignment techniques to determine whether computer-assisted navigation systems can reduce variability of tibial component rotational alignment when compared to traditional instrumentation. Eleven orthopaedic surgeons used four computer-assisted techniques that required identification of anatomical landmarks and one that used traditional extramedullary instrumentation to establish tibial rotational alignment axes on 10 cadaver legs. Two computer-assisted techniques (axes between the most medial and lateral border of the tibial plateau, and between the posterior cruciate ligament [PCL] and the anterior tibial crest) and the traditional technique were least variable, with standard deviations of 9.9 degrees, 10.8 degrees, and 12.1 degrees, respectively. Computer-assisted techniques referencing the tibial tubercle (axes between the PCL and the medial border or medial 1/3 of the tubercle) were most variable, with standard deviations of 27.4 degrees and 28.1 degrees. The axis between the medial border of the tibial tubercle and the PCL was internally rotated compared to the other techniques. None of the techniques consistently established tibial rotational alignment, and navigation systems that establish rotational alignment by identifying anatomic landmarks were not more reliable than traditional instrumentation.

Mesh:

Year:  2006        PMID: 16906095     DOI: 10.1097/01.blo.0000229335.36900.a0

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  31 in total

Review 1.  Computer assisted navigation in knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song
Journal:  Clin Orthop Surg       Date:  2011-12-01

2.  Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty.

Authors:  Stephen M Howell; Justin Chen; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-05       Impact factor: 4.342

3.  Centre of the posterior cruciate ligament and the sulcus between tubercle spines are reliable landmarks for tibial component placement.

Authors:  Namık Sahin; Teoman Atıcı; Ünal Kurtoğlu; Ali Turgut; Güven Ozkaya; Yüksel Ozkan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-03       Impact factor: 4.342

Review 4.  Rotational alignment of the tibial component in total knee arthroplasty.

Authors:  Pier Francesco Indelli; Angelo Graceffa; Massimiliano Marcucci; Andrea Baldini
Journal:  Ann Transl Med       Date:  2016-01

5.  Accuracy of side-cutting implantation instruments for total knee arthroplasty.

Authors:  Arno Martin; Mitchell B Sheinkop; Mary M Langhenry; Christian Oelsch; Mark Widemschek; Archibald von Strempel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-01-09       Impact factor: 4.342

6.  Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error.

Authors:  Csaba Forster-Horvath; Valerie Kremo; Magdalena Müller-Gerbl; Andrej Maria Nowakowski
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

7.  Comparison of two minimally invasive implantation instrument-sets for total knee arthroplasty.

Authors:  Arno Martin; Mitchell B Sheinkop; Mary M Langhenry; Mark Widemschek; Thomas Benesch; Archibald von Strempel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-22       Impact factor: 4.342

8.  Mechanical axis-derived femoral component rotation in extramedullary total knee arthroplasty: a comparison between femoral transverse axis and transepicondylar axis.

Authors:  Jai-Gon Seo; Young-Wan Moon; Ji-Soon Lim; Se-Jun Park; Sang-Min Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-13       Impact factor: 4.342

9.  Rotational alignment of the tibial component in total knee arthroplasty: the anterior tibial cortex is a reliable landmark.

Authors:  Andrea Baldini; Pier Francesco Indelli; Lapo DE Luca; Pierpaolo Cerulli Mariani; Massimiliano Marcucci
Journal:  Joints       Date:  2014-03-21

10.  Accuracy of image-free navigation for severely deformed knees.

Authors:  Minoru Takasaki; Shuichi Matsuda; Shingo Fukagawa; Hiroaki Mitsuyasu; Hiromasa Miura; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-17       Impact factor: 4.342