Literature DB >> 16905069

Mini-implant anchorage for maxillary canine retraction: a pilot study.

Robert J Herman1, G Frans Currier, Alan Miyake.   

Abstract

INTRODUCTION: This clinical pilot study evaluated the stability, surrounding soft-tissue health, and patient comfort and acceptance of a mini-implant used as anchorage for maxillary permanent canine retraction.
METHODS: The study was conducted in the Graduate Orthodontic Clinic of the University of Oklahoma College of Dentistry. The sample comprised 16 subjects who had maxillary first premolars extracted. In each patient, Ortho Implants (IMTEC, Ardmore, Okla) were placed laterally in the maxillary alveolar ridge between the roots of the permanent first molars and the second premolars by an oral surgeon. All retraction was accomplished on 0.017 x 0.025-in stainless steel archwires in 0.022-in slots by using nickel-titanium springs stretched from the implant head to the brackets on the canines.
RESULTS: Placement protocol strongly affected the stability of the implants; 1 protocol resulted in the loss of 51% of the implants (19 of 39), and the second protocol resulted in 100% stability (10 of 10). The surrounding soft tissue remained healthy around stable implants and less healthy around implants that were unstable or lost. Patient comfort was excellent in all but 1 patient. Rates of canine retraction were calculated monthly and varied widely from +6.1 to -1.5 mm per month. Excessive crown tipping into the extraction spaces was observed in 4 of the 28 retracted canines and was related to the method of ligation of the canine to the archwire.
CONCLUSIONS: Ortho Implants are adequate anchorage for maxillary canine retraction when properly placed.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16905069     DOI: 10.1016/j.ajodo.2006.02.029

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  13 in total

1.  Tooth movement rate and anchorage lost during canine retraction: A maxillary and mandibular comparison.

Authors:  Andre da C Monini; Luiz G Gandini; Alexandre P Vianna; Renato P Martins; Helder B Jacob
Journal:  Angle Orthod       Date:  2019-02-11       Impact factor: 2.079

2.  Assessment of damping capacity as an index of root proximity in self-drilling orthodontic mini-implants.

Authors:  Mitsuru Motoyoshi; Yasuki Uchida; Miho Matsuoka; Mizuki Inaba; Hiroaki Iwai; Yoko Karasawa; Noriyoshi Shimizu
Journal:  Clin Oral Investig       Date:  2013-03-22       Impact factor: 3.573

3.  Evaluation of canine retraction following periodontal distraction using NiTi coil spring and implants - A clinical study.

Authors:  Rohit Khanna; Tripti Tikku; Kiran Sachan; R P Maurya; Geeta Verma; Vivek Ojha
Journal:  J Oral Biol Craniofac Res       Date:  2014-11-29

4.  The clinical and laboratory effects of bracket type during canine distalization with sliding mechanics.

Authors:  A Alper Oz; Nursel Arici; Selim Arici
Journal:  Angle Orthod       Date:  2011-08-29       Impact factor: 2.079

5.  Success rate of miniplate anchorage for bone anchored maxillary protraction.

Authors:  Eline E B De Clerck; Gwen R J Swennen
Journal:  Angle Orthod       Date:  2011-06-30       Impact factor: 2.079

6.  Clinical factors correlated with the success rate of miniscrews in orthodontic treatment.

Authors:  Nikolaos Topouzelis; Phoebus Tsaousoglou
Journal:  Int J Oral Sci       Date:  2012-01-12       Impact factor: 6.344

7.  Comparison of temporary anchorage devices and transpalatal arch-mediated anchorage reinforcement during canine retraction.

Authors:  Defne Kecik
Journal:  Eur J Dent       Date:  2016 Oct-Dec

8.  Fracture strength of orthodontic mini-implants.

Authors:  Tatiana Feres Assad-Loss; Flávia Mitiko Fernandes Kitahara-Céia; Giordani Santos Silveira; Carlos Nelson Elias; José Nelson Mucha
Journal:  Dental Press J Orthod       Date:  2017 May-Jun

9.  Quantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach.

Authors:  A Sumathi Felicita
Journal:  Dental Press J Orthod       Date:  2017 Sep-Oct

10.  Comparison of success rates of orthodontic mini-screws by the insertion method.

Authors:  Jung Suk Kim; Seong Hwan Choi; Sang Kwon Cha; Jang Han Kim; Hwa Jin Lee; Sang Seon Yeom; Chung Ju Hwang
Journal:  Korean J Orthod       Date:  2012-10-29       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.