Literature DB >> 16900035

Bioptics: where do things stand?

Antonio Leccisotti1.   

Abstract

PURPOSE OF REVIEW: Bioptics treats complex refractive errors by combining refractive techniques with different mechanisms of action, usually using an intraocular implant (a phakic or pseudophakic intraocular lens) followed by a corneal procedure (laser ablation, intrastromal implant). RECENT
FINDINGS: In myopia and hyperopia, bioptics with phakic intraocular lenses or refractive lens exchange and subsequent excimer laser yields improved predictability and unchanged safety, compared with sole intraocular lens surgery. Complications are related mainly to intraocular lenses. In keratoconus and pellucid marginal degeneration, intracorneal rings have been successfully combined with phacoemulsification or with phakic intraocular lenses in a limited number of eyes. In the author's series, angle-supported phakic intraocular lenses were implanted in 12 eyes to correct a mean regression of -8 D after excimer laser (reverse bioptics), achieving a mean spherical equivalent of -0.3 D, mean best spectacle-corrected visual acuity of 0.7, and mean uncorrected visual acuity of 0.5, with 83% of eyes within 0.5 D of spherical equivalent.
SUMMARY: Bioptics improves vision and halos and adds no particular risks to phakic or pseudophakic intraocular lens implantation in either myopia or hyperopia. Reverse bioptics, with phakic intraocular lenses or refractive lens exchange, can be used to correct regressed corneal surgery.

Entities:  

Mesh:

Year:  2006        PMID: 16900035     DOI: 10.1097/01.icu.0000233962.19004.14

Source DB:  PubMed          Journal:  Curr Opin Ophthalmol        ISSN: 1040-8738            Impact factor:   3.761


  5 in total

1.  Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery.

Authors:  Majid Moshirfar; Michael V McCaughey; Luis Santiago-Caban
Journal:  Expert Rev Ophthalmol       Date:  2014-12

2.  Implantable collamer lens for residual refractive error after corneal refractive surgery.

Authors:  Xun Chen; Xiao-Ying Wang; Xi Zhang; Zhi Chen; Xing-Tao Zhou
Journal:  Int J Ophthalmol       Date:  2016-10-18       Impact factor: 1.779

3.  Intraocular lens calculation by intraoperative autorefraction in myopic eyes.

Authors:  Antonio Leccisotti
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2007-06-29       Impact factor: 3.117

4.  Visian implantable contact lens versus AcrySof Cachet phakic intraocular lenses: comparison of aberrmetric profiles.

Authors:  Mohamed Hm Hosny; Ahmad Mm Shalaby
Journal:  Clin Ophthalmol       Date:  2013-07-22

5.  Visual Outcomes After Sequential Posterior Chamber Phakic IOL with Corneal Refractive Surgery (Bioptics) for the Treatment of Myopic Astigmatism.

Authors:  Majid Moshirfar; Robert J Thomson; William B West Jnr; Shannon E McCabe; Thomas M Sant; Margaret H Shmunes; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Clin Ophthalmol       Date:  2020-12-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.