Literature DB >> 16896305

Renal magnetic resonance angiography at 3.0 Tesla using a 32-element phased-array coil system and parallel imaging in 2 directions.

Michael Fenchel1, Kambiz Nael, Vibhas S Deshpande, J Paul Finn, Ulrich Kramer, Stephan Miller, Stefan Ruehm, Gerhard Laub.   

Abstract

PURPOSE: The aim of the present study was to assess the feasibility of renal magnetic resonance angiography at 3.0 T using a phased-array coil system with 32-coil elements. Specifically, high parallel imaging factors were used for an increased spatial resolution and anatomic coverage of the whole abdomen.
MATERIALS AND METHODS: Signal-to-noise values and the g-factor distribution of the 32 element coil were examined in phantom studies for the magnetic resonance angiography (MRA) sequence. Eleven volunteers (6 men, median age of 30.0 years) were examined on a 3.0-T MR scanner (Magnetom Trio, Siemens Medical Solutions, Malvern, PA) using a 32-element phased-array coil (prototype from In vivo Corp.). Contrast-enhanced 3D-MRA (TR 2.95 milliseconds, TE 1.12 milliseconds, flip angle 25-30 degrees , bandwidth 650 Hz/pixel) was acquired with integrated generalized autocalibrating partially parallel acquisition (GRAPPA), in both phase- and slice-encoding direction. Images were assessed by 2 independent observers with regard to image quality, noise and presence of artifacts.
RESULTS: Signal-to-noise levels of 22.2 +/- 22.0 and 57.9 +/- 49.0 were measured with (GRAPPAx6) and without parallel-imaging, respectively. The mean g-factor of the 32-element coil for GRAPPA with an acceleration of 3 and 2 in the phase-encoding and slice-encoding direction, respectively, was 1.61. High image quality was found in 9 of 11 volunteers (2.6 +/- 0.8) with good overall interobserver agreement (k = 0.87). Relatively low image quality with higher noise levels were encountered in 2 volunteers.
CONCLUSION: MRA at 3.0 T using a 32-element phased-array coil is feasible in healthy volunteers. High diagnostic image quality and extended anatomic coverage could be achieved with application of high parallel imaging factors.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16896305     DOI: 10.1097/01.rli.0000233319.04760.a4

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  8 in total

Review 1.  Highly accelerated cardiovascular MR imaging using many channel technology: concepts and clinical applications.

Authors:  Thoralf Niendorf; Daniel K Sodickson
Journal:  Eur Radiol       Date:  2007-06-12       Impact factor: 5.315

2.  Magnetic resonance angiography of the carotid arteries: comparison of unenhanced and contrast enhanced techniques.

Authors:  Harald Kramer; Val M Runge; John N Morelli; Kenneth D Williams; L Gill Naul; Konstantin Nikolaou; Maximilian F Reiser; Bernd J Wintersperger
Journal:  Eur Radiol       Date:  2011-04-09       Impact factor: 5.315

3.  First-pass contrast-enhanced renal MRA at 7 Tesla: initial results.

Authors:  L Umutlu; S Maderwald; S Kinner; O Kraff; A K Bitz; S Orzada; S Johst; K Wrede; M Forsting; M E Ladd; T C Lauenstein; H H Quick
Journal:  Eur Radiol       Date:  2012-10-14       Impact factor: 5.315

4.  Assessment of the kidneys: magnetic resonance angiography, perfusion and diffusion.

Authors:  Ulrike I Attenberger; John N Morelli; Stefan O Schoenberg; Henrik J Michaely
Journal:  J Cardiovasc Magn Reson       Date:  2011-11-15       Impact factor: 5.364

5.  Contrast-enhanced MR angiography of the abdomen with highly accelerated acquisition techniques.

Authors:  Petrice M Mostardi; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Radiology       Date:  2011-09-07       Impact factor: 11.105

6.  Early changes with diabetes in renal medullary hemodynamics as evaluated by fiberoptic probes and BOLD magnetic resonance imaging.

Authors:  Elisabete Alcantara dos Santos; Lu-Ping Li; Lin Ji; Pottumarthi Vara Prasad
Journal:  Invest Radiol       Date:  2007-03       Impact factor: 6.016

7.  Three-dimensional contrast-enhanced magnetic-resonance angiography of the renal arteries: interindividual comparison of 0.2 mmol/kg gadobutrol at 1.5 T and 0.1 mmol/kg gadobenate dimeglumine at 3.0 T.

Authors:  Ulrike I Attenberger; Henrik J Michaely; Bernd J Wintersperger; Steven P Sourbron; Klaus-Peter Lodemann; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2008-02-16       Impact factor: 5.315

8.  PC HYPR flow: a technique for rapid imaging of contrast dynamics.

Authors:  Julia V Velikina; Kevin M Johnson; Yijing Wu; Alexey A Samsonov; Patrick Turski; Charles A Mistretta
Journal:  J Magn Reson Imaging       Date:  2010-02       Impact factor: 4.813

  8 in total