Literature DB >> 1689619

Stretch-induced arrhythmias in the isolated canine ventricle. Evidence for the importance of mechanoelectrical feedback.

D E Hansen1, C S Craig, L M Hondeghem.   

Abstract

Alterations in loading conditions and muscle length influence the electrophysiology of ventricular myocardium and may play a role in arrhythmogenesis in globally dilated or dyskinetic ventricles. To test the hypothesis that stretch can initiate arrhythmias in normal myocardium, the response to graded mechanical stretch was studied in seven isolated blood-perfused canine ventricles. After eight conditioning contractions produced by His bundle pacing (2 Hz), global stretch of the ventricle was produced by a servocontrolled pump that abruptly increased ventricular volume by a precise amount (delta V) during early diastole and then returned ventricular volume to the initial holding volume (Vi). Ventricular premature contractions were readily produced; ventricular couplets and short runs of ventricular tachycardia were occasionally elicited. The probability of a stretch-induced arrhythmia was determined from multiple alternating sequences in which a stretch of known amplitude (delta V) or no stretch was delivered. As delta V was increased, the probability of a stretch-induced arrhythmia was low initially, increased sharply after a threshold was exceeded, and approaching 100% with physiological volumes. With Vi set to a standard value of 20 ml, corresponding to end-diastolic pressure of 5.3 +/- 5.2 mm Hg (mean +/- SD), the delta V resulting in a 50% chance of a stretch-induced arrhythmia (delta V50) was 15.0 +/- 1.6 ml. A decline in delta V50 was consistently observed when Vi was increased. While delta V50 values were remarkably similar (10.7% coefficient of variation), the pressure at the time the ventricular premature depolarization was triggered was highly variable for different ventricles; this finding suggests that myocardial strain is more important than absolute level of wall stress in the initiation of these arrhythmias. These results demonstrate that myocardial stretch predictably initiates arrhythmias and that the susceptibility to stretch-induced arrhythmias is enhanced by ventricular dilatation. Thus, ventricular ectopy in patients with regionally or globally dilated hearts may arise, in part, by a mechanism of myocardial stretch.

Entities:  

Mesh:

Year:  1990        PMID: 1689619     DOI: 10.1161/01.cir.81.3.1094

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  48 in total

1.  Regional changes in ventricular excitability during load manipulation of the in situ pig heart.

Authors:  J W Dean; M J Lab
Journal:  J Physiol       Date:  1990-10       Impact factor: 5.182

Review 2.  Interaction between ventricular loading and repolarisation: relevance to arrhythmogenesis.

Authors:  P Taggart; P Sutton; M Lab
Journal:  Br Heart J       Date:  1992-03

Review 3.  Biomechanics of cardiac electromechanical coupling and mechanoelectric feedback.

Authors:  Emily R Pfeiffer; Jared R Tangney; Jeffrey H Omens; Andrew D McCulloch
Journal:  J Biomech Eng       Date:  2014-02       Impact factor: 2.097

4.  The Mechanical Bidomain Model: A Review.

Authors:  Bradley J Roth
Journal:  ISRN Tissue Eng       Date:  2013-01-01

Review 5.  Cell cultures as models of cardiac mechanoelectric feedback.

Authors:  Yibing Zhang; Rajesh B Sekar; Andrew D McCulloch; Leslie Tung
Journal:  Prog Biophys Mol Biol       Date:  2008-02-16       Impact factor: 3.667

6.  Defibrillation efficacy with endocardial electrodes is influenced by reductions in cardiac preload.

Authors:  J S Strobel; G N Kay; G P Walcott; W M Smith; R E Ideker
Journal:  J Interv Card Electrophysiol       Date:  1997-09       Impact factor: 1.900

7.  Remodeling of atrial ATP-sensitive K⁺ channels in a model of salt-induced elevated blood pressure.

Authors:  Joshua M Lader; Carolina Vasquez; Li Bao; Karen Maass; Jiaxiang Qu; Eirini Kefalogianni; Glenn I Fishman; William A Coetzee; Gregory E Morley
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-07-01       Impact factor: 4.733

Review 8.  Electrophysiological challenges of cell-based myocardial repair.

Authors:  Huei-Sheng Vincent Chen; Changsung Kim; Mark Mercola
Journal:  Circulation       Date:  2009-12-15       Impact factor: 29.690

9.  Computational prediction of the effect of D172N KCNJ2 mutation on ventricular pumping during sinus rhythm and reentry.

Authors:  Aulia Khamas Heikhmakhtiar; Chung Hao Lee; Kwang Soup Song; Ki Moo Lim
Journal:  Med Biol Eng Comput       Date:  2020-02-24       Impact factor: 2.602

10.  Three-dimensional analysis of regional mechanical function, blood flow and electrophysiological parameters during early myocardial ischemia in dogs.

Authors:  P Kowallik; D Baumgart; A Skyschally; T Ehring; G Heusch
Journal:  Basic Res Cardiol       Date:  1992 May-Jun       Impact factor: 17.165

View more