Literature DB >> 16890464

Steady-state free precession with hyperpolarized 3He: experiments and theory.

Jim M Wild1, Kevin Teh, Neil Woodhouse, Martyn N J Paley, Stan Fichele, Nicola de Zanche, Larry Kasuboski.   

Abstract

The magnetization response of hyperpolarized 3He gas to a steady-state free precession (SSFP) sequence was simulated using matrix product operators. The simulations included the effects of flip angle (alpha), sequence timings, resonant frequency, gas diffusion coefficient, imaging gradients, T1 and T2. Experiments performed at 1.5 T, on gas phantoms and with healthy human subjects, confirm the predicted theory, and indicate increased SNR with SSFP through use of higher flip angles when compared to optimized spoiled gradient echo (SPGR). Simulations and experiments show some compromise to the SNR and some point spread function broadening at high alpha due to the incomplete refocusing of transverse magnetization, caused by diffusion dephasing from the readout gradient. Mixing of gas polarization levels by diffusion between slices is also identified as a source of signal loss in SSFP at higher alpha through incomplete refocusing. Nevertheless, in the sample experiments, a SSFP sequence with an optimized flip angle of alpha=20 degrees, and 128 sequential phase encoding views, showed a higher SNR when compared to SPGR (alpha=7.2 degrees) with the same bandwidth. Some of the gas sample experiments demonstrated a transient signal response that deviates from theory in the initial phase. This was identified as being caused by radiation damping interactions between the large initial transverse magnetization and the high quality factor (Q=250) birdcage resonator. In 3He NMR experiments, performed without imaging gradients, diffusion dephasing can be mitigated, and the effective T2 is relatively long (1 s). Under these circumstances the SSFP sequence behaves like a CPMG sequence with sinalpha/2 weighting of SNR. Experiments and simulations were also performed to characterize the off-resonance behaviour of the SSFP HP 3He signal. Characteristic banding artifacts due to off-resonance harmonic beating were observed in some of the in vivo SSFP images, for instance in axial slices close to the diaphragm where B0 inhomogeneity is highest. Despite these artifacts, a higher SNR was observed with SSFP in vivo when compared to the SPGR sequence. The trends predicted by theory of increasing SSFP SNR with increasing flip angle were observed in the range alpha=10-20 degrees without compromise to image quality through blurring caused by excessive k-space filtering.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16890464     DOI: 10.1016/j.jmr.2006.07.015

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  10 in total

1.  Preclinical hyperpolarized 129 Xe MRI: ventilation and T2 * mapping in mouse lungs at 7 T using multi-echo flyback UTE.

Authors:  Peter J Niedbalski; Alexander S Cochran; Teckla G Akinyi; Robert P Thomen; Elizabeth M Fugate; Diana M Lindquist; Ronald G Pratt; Zackary I Cleveland
Journal:  NMR Biomed       Date:  2020-04-14       Impact factor: 4.044

2.  High resolution (13)C MRI with hyperpolarized urea: in vivo T(2) mapping and (15)N labeling effects.

Authors:  Galen D Reed; Cornelius von Morze; Robert Bok; Bertram L Koelsch; Mark Van Criekinge; Kenneth J Smith; Peder E Z Larson; John Kurhanewicz; Daniel B Vigneron
Journal:  IEEE Trans Med Imaging       Date:  2013-10-25       Impact factor: 10.048

Review 3.  Functional imaging of the lungs with gas agents.

Authors:  Stanley J Kruger; Scott K Nagle; Marcus J Couch; Yoshiharu Ohno; Mitchell Albert; Sean B Fain
Journal:  J Magn Reson Imaging       Date:  2015-07-27       Impact factor: 4.813

Review 4.  [Functional 3He-MRI of the lungs].

Authors:  K K Gast; U Wolf
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

5.  Ventilation and perfusion magnetic resonance imaging of the lung.

Authors:  Grzegorz Bauman; Monika Eichinger
Journal:  Pol J Radiol       Date:  2012-01

6.  Multiple breath washout of hyperpolarized 129 Xe and 3 He in human lungs with three-dimensional balanced steady-state free-precession imaging.

Authors:  Felix C Horn; Madhwesha Rao; Neil J Stewart; Jim M Wild
Journal:  Magn Reson Med       Date:  2016-07-12       Impact factor: 4.668

7.  RF instrumentation for same-breath triple nuclear lung MR imaging of (1)H and hyperpolarized (3)He and (129)Xe at 1.5T.

Authors:  Madhwesha Rao; Jim M Wild
Journal:  Magn Reson Med       Date:  2015-05-13       Impact factor: 4.668

8.  Dissolved hyperpolarized xenon-129 MRI in human kidneys.

Authors:  Jorge Chacon-Caldera; Adam Maunder; Madhwesha Rao; Graham Norquay; Oliver I Rodgers; Matthew Clemence; Claudio Puddu; Lothar R Schad; Jim M Wild
Journal:  Magn Reson Med       Date:  2019-08-09       Impact factor: 4.668

Review 9.  In vivo methods and applications of xenon-129 magnetic resonance.

Authors:  Helen Marshall; Neil J Stewart; Ho-Fung Chan; Madhwesha Rao; Graham Norquay; Jim M Wild
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2020-12-09       Impact factor: 9.795

10.  Optimization of steady-state free precession MRI for lung ventilation imaging with 19 F C3 F8 at 1.5T and 3T.

Authors:  Adam Maunder; Madhwesha Rao; Fraser Robb; Jim M Wild
Journal:  Magn Reson Med       Date:  2018-11-02       Impact factor: 4.668

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.