BACKGROUND AND PURPOSE: The potential benefits and limitations of different radiation techniques (stereotactic arc therapy (SRS/T), intensity modulated radiotherapy (IMRT), helical tomotherapy (HT), Cyberknife and intensity-modulated multiple arc therapy (AMOA)) have been assessed using comparative treatment planning methods on twelve patients presenting with 'benign' brain tumours. MATERIALS AND METHODS: Plans for five acoustic neurinomas, five meningiomas and two pituitary adenomas were computed to generate dose distributions for all modalities using a common CT dataset to delineate planning target volume and organs at risk. RESULTS: HT, AMOA and IMRT resulted superior to SRS/T and Cyberknife for target coverage. For the first group V(95%) ranged from 98% to 100%, minimum dose ranged from 91% to 96% and standard deviation from 0.84% to 1.67%. For organs at risk all techniques respected planning objectives with a tendency of Cyberknife and SRS/T to better spare the brain stem and the healthy brain tissue (e.g., V(20Gy) of 2.0% and 2.3%, respectively, compared to 3.1-5.0% for the other techniques). AMOA is in general preferable to IMRT for all OARs. Conformity index (CI(95)) was better for HT and Cyberknife (both 1.8) and less for AMOA and IMRT (3.9 and 3.0, respectively). CONCLUSION: All techniques provided good OAR sparing and primarily differed in target coverage indices. For the class of tumours investigated in this report, HT, AMOA and IMRT had better target coverage with HT providing the best combination of indeces. Between AMOA and IMRT, target coverage was comparable and, considering organs at risk, AMOA was slightly preferable.
BACKGROUND AND PURPOSE: The potential benefits and limitations of different radiation techniques (stereotactic arc therapy (SRS/T), intensity modulated radiotherapy (IMRT), helical tomotherapy (HT), Cyberknife and intensity-modulated multiple arc therapy (AMOA)) have been assessed using comparative treatment planning methods on twelve patients presenting with 'benign' brain tumours. MATERIALS AND METHODS: Plans for five acoustic neurinomas, five meningiomas and two pituitary adenomas were computed to generate dose distributions for all modalities using a common CT dataset to delineate planning target volume and organs at risk. RESULTS: HT, AMOA and IMRT resulted superior to SRS/T and Cyberknife for target coverage. For the first group V(95%) ranged from 98% to 100%, minimum dose ranged from 91% to 96% and standard deviation from 0.84% to 1.67%. For organs at risk all techniques respected planning objectives with a tendency of Cyberknife and SRS/T to better spare the brain stem and the healthy brain tissue (e.g., V(20Gy) of 2.0% and 2.3%, respectively, compared to 3.1-5.0% for the other techniques). AMOA is in general preferable to IMRT for all OARs. Conformity index (CI(95)) was better for HT and Cyberknife (both 1.8) and less for AMOA and IMRT (3.9 and 3.0, respectively). CONCLUSION: All techniques provided good OAR sparing and primarily differed in target coverage indices. For the class of tumours investigated in this report, HT, AMOA and IMRT had better target coverage with HT providing the best combination of indeces. Between AMOA and IMRT, target coverage was comparable and, considering organs at risk, AMOA was slightly preferable.
Authors: Alonso N Gutiérrez; David C Westerly; Wolfgang A Tomé; Hazim A Jaradat; Thomas R Mackie; Søren M Bentzen; Deepak Khuntia; Minesh P Mehta Journal: Int J Radiat Oncol Biol Phys Date: 2007-10-01 Impact factor: 7.038
Authors: Emilie T Soisson; Peter W Hoban; Thomas Kammeyer; Jeffrey M Kapatoes; David C Westerly; Amar Basavatia; Wolfgang A Tomé Journal: Med Dosim Date: 2011 Impact factor: 1.482
Authors: Stefanie Milker-Zabel; Peter Huber; Wolfgang Schlegel; Jürgen Debus; Angelika Zabel-du Bois Journal: J Neurooncol Date: 2009-04-01 Impact factor: 4.130
Authors: Paula Monasor Denia; María Del Carmen Castellet García; Carla Manjón García; Juan David Quirós Higueras; Noelia de Marco Blancas; Jorge Bonaque Alandí; Xavier Jordi Juan Senabre; Agustín Santos Serra; Juan López-Tarjuelo Journal: PLoS One Date: 2019-03-11 Impact factor: 3.240
Authors: Karen Chin Snyder; Justine Cunningham; Yimei Huang; Bo Zhao; Jennifer Dolan; Ning Wen; Indrin J Chetty; Mira M Shah; Salim M Siddiqui Journal: Adv Radiat Oncol Date: 2021-02-06