Literature DB >> 1688333

Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems.

J P Collier1, V A Surprenant, R E Jensen, M B Mayor.   

Abstract

The combination of a cobalt-alloy head on a titanium-alloy femoral hip stem is widely accepted for press-fit and biologic fixation applications. Examination of 30 components retrieved at periods of 0.5 to 66.9 months for histologic examination of tissue ingrowth revealed that 56.6% of the tapered connections between head and stem showed evidence of crevice corrosion leading to concerns of metal ion release and the potential failure of head to stem fixation.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1688333

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  28 in total

1.  Revision for taper corrosion at the head-neck junction: pearls and pitfalls.

Authors:  Brian J McGrory; Brigham R McKenney
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

2.  Taper design affects failure of large-head metal-on-metal total hip replacements.

Authors:  Nader A Nassif; Danyal H Nawabi; Kirsten Stoner; Marcella Elpers; Timothy Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

Review 3.  Metallic debris from metal-on-metal total hip arthroplasty regulates periprosthetic tissues.

Authors:  Christoph H Lohmann; Gurpal Singh; Hans-Georg Willert; Gottfried H Buchhorn
Journal:  World J Orthop       Date:  2014-11-18

4.  Characterization of Femoral Head Taper Corrosion Features Using a 22-Year Retrieval Database.

Authors:  Jacob Cartner; Patrick Aldinger; Chenxi Li; David Collins
Journal:  HSS J       Date:  2016-08-12

5.  Arthroscopy as a diagnostic tool for painful trunnion corrosion after hip arthroplasty.

Authors:  Michael R Whitehouse; Clive P Duncan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-07-22       Impact factor: 4.342

6.  Modern trunnions are more flexible: a mechanical analysis of THA taper designs.

Authors:  David A Porter; Robert M Urban; Joshua J Jacobs; Jeremy L Gilbert; José A Rodriguez; H John Cooper
Journal:  Clin Orthop Relat Res       Date:  2014-09-30       Impact factor: 4.176

7.  Diagnosis and Management of Adverse Reactions to Metal Debris.

Authors:  Richard A Wawrose; Kenneth L Urish
Journal:  Oper Tech Orthop       Date:  2019-10-01

8.  Mechanically assisted taper corrosion in modular TKA.

Authors:  Christina M Arnholt; Daniel W MacDonald; Mariya Tohfafarosh; Jeremy L Gilbert; Clare M Rimnac; Steven M Kurtz; Gregg Klein; Michael A Mont; Javad Parvizi; Harold E Cates; Gwo-Chin Lee; Arthur Malkani; Mattheuw Kraay
Journal:  J Arthroplasty       Date:  2014-05-28       Impact factor: 4.757

9.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

10.  Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.

Authors:  Thomas M Grupp; Thomas Weik; Wilhelm Bloemer; Hanns-Peter Knaebel
Journal:  BMC Musculoskelet Disord       Date:  2010-01-04       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.