Literature DB >> 16880875

Radiation exposure to the spinal interventionalist performing lumbar discography.

Kenneth P Botwin1, Glenn S Fuoco, Francisco M Torres, Robert D Gruber, Constantine C Bouchlas, Ramon Castellanos, Sanjiv Rao.   

Abstract

To evaluate radiation exposure to the spinal interventionalist performing lumbar discography. A prospective study on four spinal interventionalists who performed 106 consecutive lumbar discograms (levels) on 37 patients with low back pain. Radiation exposure was monitored with the assistance of a radiological technologist (RT) who allocated four (4) dosimetry badges to all spinal interventionalists performing Discograms on consecutive patients being referred for evaluation of possible discogenic pain. The badges were placed on the ring finger, glasses and both the inside and outside of the lead apron worn by the interventionalist. The mean fluoroscopy time per procedure was 57.24 seconds. The mean/cumulative exposure per procedure was 3.66(-/+0.915)/390(-/+9.750) mREM at the "ring" badge, 2.35(-/+0.635)/251(-/+6.275) mREM at the "outside apron" badge, 1.49(-/+0.373)/159(-/+3.975) mREM at the "glasses" badge. A statistically significant higher radiation exposure was found on discograms at the L5/S1 level compared to the L4/5 and L3/4 levels. Our study illustrates that radiation exposure to the spinal interventionalist performing lumbar discography is well within safety limits.

Entities:  

Year:  2003        PMID: 16880875

Source DB:  PubMed          Journal:  Pain Physician        ISSN: 1533-3159            Impact factor:   4.965


  5 in total

1.  Radiation dose to the operator during fluoroscopically guided spine procedures.

Authors:  Luca Roccatagliata; Stefano Presilla; Emanuele Pravatà; Alessandro Cianfoni
Journal:  Neuroradiology       Date:  2017-07-18       Impact factor: 2.804

2.  Radiation exposure to physicians during interventional pain procedures.

Authors:  Tae Wan Kim; Jang Hwan Jung; Hyun Joo Jeon; Kyung Bong Yoon; Duck Mi Yoon
Journal:  Korean J Pain       Date:  2010-03-10

3.  The risk of radiation exposure to the eyes of the interventional pain physician.

Authors:  David E Fish; Andrew Kim; Christopher Ornelas; Sungchan Song; Sanjog Pangarkar
Journal:  Radiol Res Pract       Date:  2011-05-17

Review 4.  Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management.

Authors:  Bo Kyung Cheon; Cho Long Kim; Ka Ram Kim; Min Hye Kang; Jeong Ae Lim; Nam Sik Woo; Ka Young Rhee; Hae Kyoung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2018-10-01

5.  Radiation exposure to the eyes and thyroid during C-arm fluoroscopy-guided cervical epidural injections is far below the safety limit.

Authors:  Eun Joo Choi; Gwangcheol Go; Woong Ki Han; Pyung-Bok Lee
Journal:  Korean J Pain       Date:  2020-01-01
  5 in total