Literature DB >> 16878891

On-chip enzyme immunoassay of a cardiac marker using a microfluidic device combined with a portable surface plasmon resonance system.

Ryoji Kurita1, Yoshimi Yokota, Yukari Sato, Fumio Mizutani, Osamu Niwa.   

Abstract

This paper reports a miniaturized immunosensor designed to determine a trace level cardiac marker, B-type natriuretic peptide (BNP), using a microfluidic device combined with a portable surface plasmon resonance (SPR) sensor system. Sample BNP solution was introduced into the microchannel after an immunoreaction with acetylcholine esterase-labeled antibody (conjugate), and only unbound conjugate was trapped on the BNP-immobilized surface in the flow channel. Then, the thiol compound generated by the enzymatic reaction with the trapped conjugate was accumulated on a gold thin film located downstream in the microchannel to monitor the real-time SPR angle shift. We achieved a detectable concentration range of 5 pg/mL-100 ng/mL by monitoring the SPR angle shift, which covers the required detection range for the BNP concentrations found in blood. This success resulted from the use of a T-shaped microfluidic device structure, which prevents the sample solution from flowing over the gold film used for SPR detection. We were able to measure trace levels of BNP peptide (15 fg) within 30 min since the procedure with our immunosensor is simpler than a multistep immunoassay through the simultaneous use of a labeled enzymatic reaction and the real-time monitoring of enzymatic product accumulation in the microfluidic device. We employed the procedure to detect serum BNP by using spiked samples in human serum and achieved satisfactory recovery for heat-treated samples to denature the esterase in the serum before the immunoreaction.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16878891     DOI: 10.1021/ac060480y

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  29 in total

1.  Surface plasmon resonance aided electrochemical immunosensor for CK-MB determination in undiluted serum samples.

Authors:  Fernando Garay; Greggory Kisiel; Aiping Fang; Erno Lindner
Journal:  Anal Bioanal Chem       Date:  2010-05-08       Impact factor: 4.142

2.  Pre-binding dynamic range and sensitivity enhancement for immuno-sensors using nanofluidic preconcentrator.

Authors:  Ying-Chih Wang; Jongyoon Han
Journal:  Lab Chip       Date:  2008-01-14       Impact factor: 6.799

3.  Real-time and Label-free Bio-sensing of Molecular Interactions by Surface Plasmon Resonance: A Laboratory Medicine Perspective.

Authors:  Erik Helmerhorst; David J Chandler; Matt Nussio; Cyril D Mamotte
Journal:  Clin Biochem Rev       Date:  2012-11

4.  Flow-through immunosensors using antibody-immobilized polymer monoliths.

Authors:  Jikun Liu; Chien-Fu Chen; Chih-Wei Chang; Don L DeVoe
Journal:  Biosens Bioelectron       Date:  2010-06-11       Impact factor: 10.618

5.  Functional expression of recombinant anti-BNP scFv in methylotrophic yeast Pichia pastoris and application as a recognition molecule in electrochemical sensors.

Authors:  Bo Hee Maeng; Jeongyeon Choi; Young Seung Sa; Jae Ho Shin; Yong Hwan Kim
Journal:  World J Microbiol Biotechnol       Date:  2011-09-25       Impact factor: 3.312

6.  Nanoporous Glass Integrated in Volumetric Bar-Chart Chip for Point-of-Care Diagnostics of Non-Small Cell Lung Cancer.

Authors:  Ying Li; Jie Xuan; Yujun Song; Wenjin Qi; Bangshun He; Ping Wang; Lidong Qin
Journal:  ACS Nano       Date:  2015-12-28       Impact factor: 15.881

7.  Shadow masking for nanomaterial-based biosensors incorporated with a microfluidic device.

Authors:  Jiyong Huang; Innam Lee; Xiliang Luo; Xinyan Tracy Cui; Minhee Yun
Journal:  Biomed Microdevices       Date:  2013-06       Impact factor: 2.838

8.  Imaging of surfaces by concurrent surface plasmon resonance and surface plasmon resonance-enhanced fluorescence.

Authors:  Rahber Thariani; Paul Yager
Journal:  PLoS One       Date:  2010-03-25       Impact factor: 3.240

Review 9.  Systems biology coupled with label-free high-throughput detection as a novel approach for diagnosis of chronic obstructive pulmonary disease.

Authors:  Joanna L Richens; Richard A Urbanowicz; Elizabeth A M Lunt; Rebecca Metcalf; Jonathan Corne; Lucy Fairclough; Paul O'Shea
Journal:  Respir Res       Date:  2009-04-22

10.  Internally calibrated quantification of protein analytes in human serum by fluorescence immunoassays in disposable elastomeric microfluidic devices.

Authors:  Emil P Kartalov; David H Lin; David T Lee; William F Anderson; Clive R Taylor; Axel Scherer
Journal:  Electrophoresis       Date:  2008-12       Impact factor: 3.535

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.