Literature DB >> 16878837

The effect of interference screw diameter on soft tissue graft fixation.

Suk Namkoong1, Christian S Heywood, Jonathan T Bravman, Kazuho Ieyasa, Frederick J Kummer, Robert J Meislin.   

Abstract

Tibial fixation of soft-tissue grafts is a weak link in anterior cruciate ligament reconstruction. Previous studies have examined varying interference screw lengths, screw types and tunnel sizes as means to improve graft fixation. We hypothesized that increasing interference screw diameter would significantly increase the maximum load to failure of the graft and decrease the graft's initial slippage. Seventy tibialis anterior and tibialis posterior tendons were divided, looped, trimmed, and sutured to simulate 4-strand hamstring grafts. These grafts were then inserted into composite bone blocks having pre-drilled 8 mm holes and fixed with 8 mm, 9 mm, 10 mm, 11 mm, or 12 mm interference screws. Fourteen grafts were tested for each screw size. The graft was first cyclically loaded from 50 N to 250 N at 0.3 Hz for 100 cycles to measure graft slippage. The graft was then tested to failure at 0.5 mm/sec to determine the maximum load to failure and mode of failure. Graft slippage was not affected by screw diameter. Maximum load to failure increased with increasing screw diameter up to 11 mm; 11 mm screw fixation was 20% stronger than 8 mm screw fixation. In this model, no increase in graft fixation was seen in by increasing interference screw diameter beyond 3 mm of the tunnel diameter.

Mesh:

Year:  2006        PMID: 16878837

Source DB:  PubMed          Journal:  Bull Hosp Jt Dis        ISSN: 0018-5647


  4 in total

1.  Elongation of simulated whipstitch post anterior cruciate ligament reconstruction tibial fixation after cyclic loading.

Authors:  Chadwick C Prodromos; Aaron Hecker; Brian Joyce; Susan Finkle; Kelvin Shi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-19       Impact factor: 4.342

2.  Close-looped graft suturing improves mechanical properties of interference screw fixation in ACL reconstruction.

Authors:  María Prado; Belén Martín-Castilla; Alejandro Espejo-Reina; José Miguel Serrano-Fernández; Ana Pérez-Blanca; Francisco Ezquerro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-30       Impact factor: 4.342

3.  Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study.

Authors:  Antonio Herrera; Fernando Martínez; Daniel Iglesias; José Cegoñino; Elena Ibarz; Luis Gracia
Journal:  BMC Musculoskelet Disord       Date:  2010-06-30       Impact factor: 2.362

4.  Significant Loss of ACL Graft Force With Tibial-Sided Soft Tissue Interference Screw Fixation Over 24 Hours: A Biomechanical Study.

Authors:  Philipp Kruppa; Anne Flies; Dag Wulsten; Robert Collette; Georg N Duda; Klaus-Dieter Schaser; Roland Becker; Sebastian Kopf
Journal:  Orthop J Sports Med       Date:  2020-05-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.