Literature DB >> 16878343

High-throughput screening for multi-class veterinary drug residues in animal muscle using liquid chromatography/tandem mass spectrometry with on-line solid-phase extraction.

Hubert Po-On Tang1, Clare Ho, Shirley Sau-Ling Lai.   

Abstract

A rapid qualitative method using on-line column-switching liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for screening 13 target veterinary drugs: four macrolides - erythromycin A, josamycin (leucomycin A3), kitasamycin (leucomycin A5), and tylosin A; six (fluoro)quinolones - ciprofloxacin, danofloxacin, enrofloxacin, flumequine, oxolinic acid, and sarafloxacin; and lincomycin, virginiamycin M1, and trimethoprim in different animal muscles. Clindamycin, norfloxacin, nalidixic acid, oleandomycin, ormetoprim, and roxithromycin were used as the internal standards. After simple deproteination and analyte extraction of muscle samples using acetonitrile, the supernatant was subjected to on-line cleanup and direct analysis by LC/MS/MS. On-line cleanup with an extraction cartridge packed with hydrophilic-hydrophobic polymer sorbent followed by fast LC using a short C18 column resulted in a total analysis cycle of 6 min for 19 drugs. This screening method considerably reduced the time and the cost for the quantitative and confirmatory analyses. The application of a control point approach was also introduced and explained. Copyright (c) 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16878343     DOI: 10.1002/rcm.2635

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

1.  A microfluidic platform for high-sensitivity, real-time drug screening on C. elegans and parasitic nematodes.

Authors:  John A Carr; Archana Parashar; Richard Gibson; Alan P Robertson; Richard J Martin; Santosh Pandey
Journal:  Lab Chip       Date:  2011-06-06       Impact factor: 6.799

2.  An integrated fiber-optic microfluidic device for detection of muscular force generation of microscopic nematodes.

Authors:  Peng Liu; Depeng Mao; Richard J Martin; Liang Dong
Journal:  Lab Chip       Date:  2012-07-24       Impact factor: 6.799

3.  Adsorptive stripping voltammetric determination of Tetracycline in pharmaceutical capsule formulation using Poly(Malachite green) modified glassy carbon electrode.

Authors:  Mahilet Turbale; Amsalu Moges; Mulugeta Dawit; Meareg Amare
Journal:  Heliyon       Date:  2020-12-23

4.  Evaluation of Antibiotic Residues in Raw Meat Using Different Analytical Methods.

Authors:  Tsepo Ramatla; Lubanza Ngoma; Modupeade Adetunji; Mulunda Mwanza
Journal:  Antibiotics (Basel)       Date:  2017-12-07
  4 in total