Literature DB >> 16873777

Is self-monitoring of blood glucose appropriate for all type 2 diabetic patients? The Fremantle Diabetes Study.

Wendy A Davis1, David G Bruce, Timothy M E Davis.   

Abstract

OBJECTIVE: We sought to determine whether self-monitoring of blood glucose (SMBG) is associated with better glycemic control in type 2 diabetes. RESEARCH DESIGN AND METHODS: We used cross-sectional and longitudinal data from type 2 diabetic participants in the observational, community-based Fremantle Diabetes Study (FDS) who reported SMBG status at study entry (n = 1,286) and annual reviews over 5 years (n = 531).
RESULTS: At study entry, 70% of patients performed SMBG, with a median of four tests per week (interquartile range two to seven). Patients with shorter diabetes duration; who were attending diabetes education, diabetes-related clinics, or medical specialists; who were taking insulin with or without oral hypoglycemic agents (OHAs); and who were self-reporting hypoglycemic events were more likely to use SMBG. Both cross-sectional and longitudinal FDS data showed that HbA(1c) (A1C) was not significantly different between SMBG users and nonusers, either overall or within diabetes treatment groups (diet, OHAs, and insulin with or without OHAs). There was also no independent cross-sectional relationship between A1C and SMBG frequency. The average annual societal cost of using SMBG (in year 2000 Australian dollars [Adollars], excluding glucometers) was 162 Australian dollars per type 2 diabetic patient or 51 million Australian dollars when projected to the Australian diagnosed type 2 diabetic population.
CONCLUSIONS: Neither SMBG testing nor its frequency was associated with glycemic benefit in type 2 diabetic patients regardless of treatment. Our data did not include methods of SMBG delivery and application, factors that require further assessment in the evaluation of SMBG utility in non-insulin-treated type 2 diabetes. SMBG may be still of value in the identification and prevention of hypoglycemia and in dose adjustment in insulin-treated patients.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16873777     DOI: 10.2337/dc06-0268

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  18 in total

1.  Self monitoring of blood glucose - a survey of diabetes UK members with type 2 diabetes who use SMBG.

Authors:  Katharine D Barnard; Amanda J Young; Norman R Waugh
Journal:  BMC Res Notes       Date:  2010-11-22

2.  Type 2 diabetes phenotype and progression is significantly different if diagnosed before versus after 65 years of age.

Authors: 
Journal:  J Diabetes Sci Technol       Date:  2008-01

3.  Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

Authors:  David B Sacks; Mark Arnold; George L Bakris; David E Bruns; Andrea Rita Horvath; M Sue Kirkman; Ake Lernmark; Boyd E Metzger; David M Nathan
Journal:  Diabetes Care       Date:  2011-06       Impact factor: 19.112

4.  Real-world Benefits of Diabetes Management App Use and Self-monitoring of Blood Glucose on Glycemic Control: Retrospective Analyses.

Authors:  Ya-Ting Chang; Yu-Zhen Tu; Hung-Yi Chiou; Ken Lai; Neng Chun Yu
Journal:  JMIR Mhealth Uhealth       Date:  2022-06-15       Impact factor: 4.947

5.  Self-monitoring of blood glucose in type 2 diabetes: an inter-country comparison.

Authors: 
Journal:  Diabetes Res Clin Pract       Date:  2008-11-07       Impact factor: 5.602

6.  Self-measurement of blood glucose in patients with type 2 diabetes: a health economic assessment.

Authors:  Christian Weber; Kurt Neeser; Berthold Schneider; Volker Lodwig
Journal:  J Diabetes Sci Technol       Date:  2007-09

7.  Blood glucose monitoring is associated with better glycemic control in type 2 diabetes: a database study.

Authors:  Glen H Murata; William C Duckworth; Jayendra H Shah; Christopher S Wendel; M Jane Mohler; Richard M Hoffman
Journal:  J Gen Intern Med       Date:  2008-10-31       Impact factor: 5.128

8.  Cost of Self-Monitoring of Blood Glucose in Canada among Patients on an Insulin Regimen for Diabetes.

Authors:  Jason Yeaw; Won Chan Lee; Michael Lyng Wolden; Torsten Christensen; Danielle Groleau
Journal:  Diabetes Ther       Date:  2012-06-27       Impact factor: 2.945

9.  A longitudinal study into the new and long-term use of self-monitoring blood glucose strips in the UK.

Authors:  C L Morgan; A Griffin; G H Chamberlain; A Turkiendorf; P McEwan; L M Evans; D R Owens
Journal:  Diabetes Ther       Date:  2010-07-28       Impact factor: 2.945

10.  Improvement of HbA(1c) and stable weight loss 2 years after an outpatient treatment and teaching program for patients with type 2 diabetes without insulin therapy based on urine glucose self-monitoring.

Authors:  Nicolle Müller; Daniela Stengel; Christof Kloos; Michael Ristow; Gunter Wolf; Ulrich A Müller
Journal:  Int J Gen Med       Date:  2012-03-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.