Literature DB >> 16872932

Influence of thermal and mechanical stresses on the strength of intact and relined denture bases.

Rosangela Seiko Seo1, Hiroshi Murata, Guang Hong, Carlos Eduardo Vergani, Taizo Hamada.   

Abstract

STATEMENT OF PROBLEM: Denture bases may become increasingly weaker as a result of thermal stress and flexural cyclic loading. Information regarding this potential problem and its relationship to the denture base reline is limited.
PURPOSE: This study evaluated the influence of thermal and mechanical stresses on the strength of intact and relined denture bases.
MATERIAL AND METHODS: Twenty-eight microwave-polymerized (Acron MC) intact denture bases were prepared in the shape of a 3-mm-thick maxillary denture. Additionally, fifty-six 2-mm-thick denture bases were relined with 1 mm of autopolymerizing resin (Tokuyama Rebase Fast II or New Truliner) (n=28). Intact and relined specimens were divided into 4 groups (n=7) as follows: without stress (control); a mechanical stress at 0.8 Hz for 10,000 cycles; 5000 thermal cycles between 5 degrees C and 55 degrees C; or a combination thermo-mechanical stress. The specimens were vertically loaded in compression with a rounded rod at 5 mm/min until failure, using a universal testing machine. Data on maximum fracture load (N), deflection at fracture (%), and fracture energy (N.mm) were analyzed by 2-way analysis of variance and Student-Newman-Keuls tests (alpha=.05).
RESULTS: The strength of the denture bases relined with New Truliner was not significantly affected by any of the experimental conditions, but comparing the control groups, New Truliner exhibited the lowest maximum fracture load values. The maximum fracture load of intact denture bases (P=.002) and those relined with Tokuyama Rebase Fast II (P=.01) showed a significant decrease after thermal stress. Additionally, cyclic loading significantly decreased the maximum fracture load (P<.001), deflection at fracture (P=.025), and fracture energy (P<.001) of intact denture bases and those relined with Tokuyama Rebase (P values of .002, .039, and .001, respectively).
CONCLUSION: Thermal and mechanical stresses exert deleterious effects on the strength of intact and/or relined denture bases, which vary according to the relining material used.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16872932     DOI: 10.1016/j.prosdent.2006.05.007

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

Review 1.  Resilient liners: a review.

Authors:  Shobha Rodrigues; Vidya Shenoy; Thilak Shetty
Journal:  J Indian Prosthodont Soc       Date:  2012-07-06

2.  Elastic modulus and flexural strength comparisons of high-impact and traditional denture base acrylic resins.

Authors:  Nour M Ajaj-Alkordy; Mohannad H Alsaadi
Journal:  Saudi Dent J       Date:  2013-12-19

3.  Impact strength of denture base and reline acrylic resins: An in vitro study.

Authors:  Ana L Machado; Bruna C Bochio; Amanda F Wady; Janaina H Jorge; Sebastião V Canevarolo; Carlos E Vergani
Journal:  J Dent Biomech       Date:  2012-09-12

4.  Mechanical Properties Evaluation of Three Different Materials for Implant Supported Overdenture: An In-Vitro Study.

Authors:  Mona Gibreel; Leila Perea-Lowery; Lippo Lassila; Pekka K Vallittu
Journal:  Materials (Basel)       Date:  2022-10-02       Impact factor: 3.748

5.  Factors affecting the bond strength of denture base and reline acrylic resins to base metal materials.

Authors:  Naomi Tanoue; Yasuhiro Matsuda; Hiroaki Yanagida; Hideo Matsumura; Takashi Sawase
Journal:  J Appl Oral Sci       Date:  2013 Jul-Aug       Impact factor: 2.698

6.  The Influence of Thermocycling on the Flexural Strength of a Polyamide Denture Base Material.

Authors:  Nick Polychronakis; Aspasia Sarafianou; Alcibiadis Zissis; Triantafillos Papadopoulos
Journal:  Acta Stomatol Croat       Date:  2017-12

7.  Effects of relining materials on the flexural strength of relined thermoplastic denture base resins.

Authors:  Yunhan Sun; So-Yeon Song; Ki-Sun Lee; Jin-Hong Park; Jae-Jun Ryu; Jeong-Yol Lee
Journal:  J Adv Prosthodont       Date:  2018-10-22       Impact factor: 1.904

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.