Literature DB >> 16872084

Peripheral doses in CyberKnife radiosurgery.

Paula L Petti1, Cynthia F Chuang, Vernon Smith, David A Larson.   

Abstract

The purpose of this work is to measure the dose outside the treatment field for conformal CyberKnife treatments, to compare the results to those obtained for similar treatments delivered with gamma knife or intensity-modulated radiation therapy (IMRT), and to investigate the sources of peripheral dose in CyberKnife radiosurgery. CyberKnife treatment plans were developed for two hypothetical lesions in an anthropomorphic phantom, one in the thorax and another in the brain, and measurements were made with LiF thermoluminescent dosimeters (TLD-100 capsules) placed within the phantom at various depths and distances from the irradiated volume. For the brain lesion, gamma knife and 6-MV IMRT treatment plans were also developed, and peripheral doses were measured at the same locations as for the CyberKnife plan. The relative contribution to the CyberKnife peripheral dose from inferior- or superior-oblique beams entering or exiting through the body, internally scattered radiation, and leakage radiation was assessed through additional experiments using the single-isocenter option of the CyberKnife treatment-planning program with different size collimators. CyberKnife peripheral doses (in cGy) ranged from 0.16 to 0.041% (+/- 0.003%) of the delivered number of monitor units (MU) at distances between 18 and 71 cm from the field edge. These values are two to five times larger than those measured for the comparable gamma knife brain treatment, and up to a factor of four times larger those measured in the IMRT experiment. Our results indicate that the CyberKnife peripheral dose is due largely to leakage radiation, however at distances less than 40 cm from the field edge, entrance, or exit dose from inferior- or superior-oblique beams can also contribute significantly. For distances larger than 40 cm from the field edge, the CyberKnife peripheral dose is directly related to the number of MU delivered, since leakage radiation is the dominant component.

Entities:  

Mesh:

Year:  2006        PMID: 16872084     DOI: 10.1118/1.2198173

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments.

Authors:  Erika Di Betta; Laura Fariselli; Achille Bergantin; Federica Locatelli; Antonella Del Vecchio; Sara Broggi; Maria Luisa Fumagalli
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

2.  Brain Damage and Patterns of Neurovascular Disorder after Ionizing Irradiation. Complications in Radiotherapy and Radiation Combined Injury.

Authors:  Nikolai V Gorbunov; Juliann G Kiang
Journal:  Radiat Res       Date:  2021-07-01       Impact factor: 2.841

3.  EURADOS strategic research agenda: vision for dosimetry of ionising radiation.

Authors:  W Rühm; E Fantuzzi; R Harrison; H Schuhmacher; F Vanhavere; J Alves; J F Bottollier Depois; P Fattibene; Ž Knežević; M A Lopez; S Mayer; S Miljanić; S Neumaier; P Olko; H Stadtmann; R Tanner; C Woda
Journal:  Radiat Prot Dosimetry       Date:  2015-03-09       Impact factor: 0.972

4.  Influence of Specific Treatment Parameters on Nontarget and Out-of-Field Doses in a Phantom Model of Prostate SBRT with CyberKnife and TrueBeam.

Authors:  Marta Kruszyna-Mochalska; Agnieszka Skrobala; Piotr Romanski; Adam Ryczkowski; Wiktoria Suchorska; Katarzyna Kulcenty; Igor Piotrowski; Dorota Borowicz; Kinga Graczyk; Natalia Matuszak; Julian Malicki
Journal:  Life (Basel)       Date:  2022-04-23

5.  Quality of radiosurgery for single brain metastases with respect to treatment technology: a matched-pair analysis.

Authors:  Berndt Wowra; Alexander Muacevic; Jörg-Christian Tonn
Journal:  J Neurooncol       Date:  2009-02-01       Impact factor: 4.130

Review 6.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

7.  Consideration of the radiation dose delivered away from the treatment field to patients in radiotherapy.

Authors:  Michael L Taylor; Tomas Kron
Journal:  J Med Phys       Date:  2011-04

8.  Peripheral doses in patients undergoing Cyberknife treatment for intracranial lesions. A single centre experience.

Authors:  Vassiliki Vlachopoulou; Christos Antypas; Harry Delis; Argyrios Tzouras; Nikolaos Salvaras; Dimitrios Kardamakis; George Panayiotakis
Journal:  Radiat Oncol       Date:  2011-11-14       Impact factor: 3.481

9.  Evaluation of Healthy Tissue Dose at Different Regions between Volumetric-Modulated Arc Therapy and Intensity-Modulated Radiation Therapy Plans in the Treatment of Various Cancers.

Authors:  Jayapalan Krishnan; Suresh Rao; Sanath Hegde; Jayarama Shetty
Journal:  J Med Phys       Date:  2019 Jul-Sep

10.  Integral dose and radiation-induced secondary malignancies: comparison between stereotactic body radiation therapy and three-dimensional conformal radiotherapy.

Authors:  Marco D'Arienzo; Stefano G Masciullo; Vitaliana de Sanctis; Mattia F Osti; Laura Chiacchiararelli; Riccardo M Enrici
Journal:  Int J Environ Res Public Health       Date:  2012-11-19       Impact factor: 3.390

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.