Literature DB >> 16872060

Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors.

Valéry Olivier Zilio1, Om Parkash Joneja, Youri Popowski, Anatoly Rosenfeld, Rakesh Chawla.   

Abstract

Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an 192Ir source. Measured radial dose rate distributions in water for different planes perpendicular to the source axis are presented and special attention is paid to the calibration of the R and K type detectors, and to the determination of appropriate correction factors for the sensitivity variation with the increase of the threshold voltage and the energy dependence. The experimental results are compared with Monte Carlo simulated dose rate distributions. The experimental results show a good agreement with the Monte Carlo simulations: the discrepancy between experimental and Monte Carlo results being within 5% for 82% of the points and within 10% for 95% of the points. Moreover, all points except two are found to lie within the experimental uncertainties, confirming thereby the quality of the results obtained.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16872060     DOI: 10.1118/1.2198168

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  On the use of a single-fiber multipoint plastic scintillation detector for 192Ir high-dose-rate brachytherapy.

Authors:  François Therriault-Proulx; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

2.  Technical note: removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: a relevant and necessary step.

Authors:  Francois Therriault-Proulx; Sam Beddar; Tina M Briere; Louis Archambault; Luc Beaulieu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

3.  A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO.

Authors:  Larry A DeWerd; Geoffrey S Ibbott; Ali S Meigooni; Michael G Mitch; Mark J Rivard; Kurt E Stump; Bruce R Thomadsen; Jack L M Venselaar
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

4.  A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy.

Authors:  Francois Therriault-Proulx; Tina M Briere; Firas Mourtada; Sylviane Aubin; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

Review 5.  In vivo dosimetry: trends and prospects for brachytherapy.

Authors:  G Kertzscher; A Rosenfeld; S Beddar; K Tanderup; J E Cygler
Journal:  Br J Radiol       Date:  2014-07-08       Impact factor: 3.039

6.  Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect.

Authors:  Masayori Ishikawa; Naomi Nagase; Taeko Matsuura; Junichi Hiratsuka; Ryusuke Suzuki; Naoki Miyamoto; Kenneth Lee Sutherland; Katsuhisa Fujita; Hiroki Shirato
Journal:  J Radiat Res       Date:  2015-01-23       Impact factor: 2.724

7.  Assessment of female breast dose for thoracic cone-beam CT using MOSFET dosimeters.

Authors:  Wenzhao Sun; Bin Wang; Bo Qiu; Jian Liang; Weihao Xie; Xiaowu Deng; Zhenyu Qi
Journal:  Oncotarget       Date:  2017-03-21

8.  Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

Authors:  Antony Palmer; David Bradley; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-06-30

9.  Characterization of MOSkin detector for in vivo skin dose measurement during megavoltage radiotherapy.

Authors:  Wei Loong Jong; Jeannie Hsiu Ding Wong; Ngie Min Ung; Kwan Hoong Ng; Gwo Fuang Ho; Dean L Cutajar; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

10.  Quality assurance during interstitial brachytherapy: in vivo dosimetry using MOSFET dosimeters.

Authors:  Corinna Melchert; Tamer Soror; György Kovács
Journal:  J Contemp Brachytherapy       Date:  2018-06-28
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.