Literature DB >> 16862006

Pulsatile perfused porcine coronary arteries for microvascular training.

Harald Schoffl1, Dietmar Hager, Christian Hinterdorfer, Karin M Dunst, Stefan Froschauer, Wolfgang Steiner, Oskar Kwasny, Georg M Huemer.   

Abstract

Microsurgery is today an established technique in specialties such as plastic surgery, neurosurgery, and trauma surgery. However, specialized training is a prerequisite for mastering anastomosis of small-diameter vessels or coaptation of nerves in the operating room. The training should be as realistic as possible and thus, laboratory animals such as the rat are preferably used as a substitute. In an attempt to minimize the use of living animals without jeopardizing a realistic training setting, we developed a pulsatile perfused porcine coronary artery model for microsurgical education. The training model consists of a membrane pump that generates a pulsatile flow within a coronary artery of a porcine heart. The pump is commercially available with a dimension of approximately 130 x 100 x 60 mm and a weight of 190 g. The pump is energized by 220 B and the motor is run on a transformed power of approximately 12 V (range, 1.5-12 V). Different fluids from simple saline solution to theoretically whole blood can be used for perfusion. The membrane pump proved to be very reliable during microvascular training because of its convenient size and wide range of feed rate providing a very realistic training setting. A maximum fluid output of 850 mL/min can be achieved. The pump has a high acceptance in microsurgical trainees evaluated by questionnaires during several microsurgical courses. The pulsatile perfused porcine coronary artery system for microsurgical training enables the trainee to work under the most realistic training settings. It proved to be a valuable tool during microsurgical education, reducing the costs and sparing living laboratory animals. Thus, we can recommend this system to anyone who is involved in training and teaching microsurgical skills.

Entities:  

Mesh:

Year:  2006        PMID: 16862006     DOI: 10.1097/01.sap.0000215248.70308.ae

Source DB:  PubMed          Journal:  Ann Plast Surg        ISSN: 0148-7043            Impact factor:   1.539


  5 in total

1.  A Novel Perforator Flap Training Model Using a Chicken Leg.

Authors:  Ignacio J Cifuentes; Ricardo A Yañez; Maria C Salisbury; José R Rodriguez; Julian E Varas; Bruno L Dagnino
Journal:  J Hand Microsurg       Date:  2016-04

2.  In vivo porcine training model of laparoscopic common bile duct repair with T-tube insertion under the situation of iatrogenic common bile duct injury.

Authors:  Eun Young Kim; Tae Ho Hong
Journal:  Ann Surg Treat Res       Date:  2018-02-28       Impact factor: 1.859

3.  Mechanical strength and hydrostatic testing of VIVO adhesive in sutureless microsurgical anastomoses: an ex vivo study.

Authors:  Marius Heitzer; Julia Brockhaus; Kristian Kniha; Felix Merkord; Florian Peters; Frank Hölzle; Evgeny Goloborodko; Ali Modabber
Journal:  Sci Rep       Date:  2021-06-30       Impact factor: 4.379

4.  Optical magnification should be mandatory for microsurgery: scientific basis and clinical data contributing to quality assurance.

Authors:  Harald Schoeffl; Davide Lazzeri; Richard Schnelzer; Stefan M Froschauer; Georg M Huemer
Journal:  Arch Plast Surg       Date:  2013-03-11

5.  The rat choledochojejunostomy model for microsurgical training.

Authors:  Jun Suh Lee; Tae Ho Hong
Journal:  Ann Surg Treat Res       Date:  2016-05-02       Impact factor: 1.859

  5 in total