Literature DB >> 16861562

Thoracoabdominal-aortoiliac MDCT angiography using reduced dose of contrast material.

Shigeto Kubo1, Eiji Tadamura, Masaki Yamamuro, Ryohei Hosokawa, Takeshi Kimura, Toru Kita, Masashi Komeda, Kaori Togashi.   

Abstract

OBJECTIVE: The objective of our study was to compare the image quality of MDCT angiography studies obtained by injection of low doses of contrast medium with saline flush versus conventional doses of contrast medium.
MATERIALS AND METHODS: Seventy-one patients with pre- or postoperative aortic aneurysms underwent MDCT angiography throughout the thoracoabdominal-aortoiliac system using an 8-MDCT scanner. In 37 patients, 100 mL of contrast medium was injected at a flow rate of 3.0 mL/s (hereafter referred to as the 100-mL group). In 34 patients, 50 mL of contrast medium followed by a 20-mL saline flush was injected at a flow rate of 2.5 mL/s (the 50-mL group). For each group, quantitative analysis involved calculating the mean aortoiliac enhancement, plateau deviation, and contrast enhancement in the pulmonary trunk and superior vena cava (SVC). Qualitative analysis involved assessing the 3D postprocessing images.
RESULTS: Significant differences between the groups in mean aortoiliac enhancement (100-mL group vs 50-mL group, 337 +/- 6 H vs 319 +/- 5 H, p < 0.0001) and mean plateau deviation (51 +/- 4 H vs 58 +/- 4 H, p < 0.0001) were found. However, adequate arterial enhancement (>or= 200 H) was observed in 31 of 34 patients in the 50-mL group and uniform aortoiliac enhancement (< 50 H) was seen in 26 patients. Visual analysis showed no difference in contrast material magnitude and homogeneity between the groups. Furthermore, in the 50-mL group, the thoracic aorta was more clearly visualized because of a reduction in the opacity of the main pulmonary artery and SVC.
CONCLUSION: In our experience, administration of 50 mL of contrast medium followed by a 20-mL saline flush produces thoracoabdominal-aortoiliac MDCT angiographic examinations of effective quality in most cases.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16861562     DOI: 10.2214/AJR.05.0309

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Optimisation of contrast medium volume and injection-related factors in CT pulmonary angiography: 64-slice CT study.

Authors:  Selma Uysal Ramadan; Pinar Kosar; Iclal Sonmez; Sevilay Karahan; Ugur Kosar
Journal:  Eur Radiol       Date:  2010-05-01       Impact factor: 5.315

2.  Comparison of different volumes of saline flush in the assessment of perivenous artefacts in the subclavian vein during cervical CT angiography.

Authors:  N Takeyama; Y Ohgiya; T Hayashi; T Takahashi; D Takasu; J Nakashima; K Kato; Y Kinebuchi; T Hashimoto; T Gokan
Journal:  Br J Radiol       Date:  2010-11-02       Impact factor: 3.039

3.  Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study.

Authors:  D Ippolito; C Talei Franzesi; D Fior; P A Bonaffini; O Minutolo; S Sironi
Journal:  Br J Radiol       Date:  2015-03-18       Impact factor: 3.039

4.  64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement.

Authors:  Daniele Marin; Rendon C Nelson; Antonino Guerrisi; Huiman Barnhart; Sebastian T Schindera; Roberto Passariello; Carlo Catalano
Journal:  Eur Radiol       Date:  2011-05-11       Impact factor: 5.315

5.  Arterial attenuation in individualized computed tomography pulmonary angiography injection protocol adjusted based on the patient's body mass index.

Authors:  Leila Jamali; Babak Alikhani; Tobias Getzin; Kristina Imeen Ringe; Frank K Wacker; Hans-Jürgen Raatschen
Journal:  J Res Med Sci       Date:  2020-10-28       Impact factor: 1.852

6.  Diagnostic value of iterative reconstruction algorithm in low kV CT angiography (CTA) with low contrast medium volume for transcatheter aortic valve implantation (TAVI) planning: image quality and radiation dose exposure.

Authors:  Cammillo R Talei Franzesi; Davide Ippolito; Luca Riva; Davide Fior; Cecilia Cangiotti; Sandro Sironi
Journal:  Br J Radiol       Date:  2018-08-13       Impact factor: 3.039