Literature DB >> 16861058

Detection of partial endotracheal tube obstruction by forced pressure oscillations.

Stefan Schumann1, Michael Lichtwarck-Aschoff, Christoph Haberthür, Claudius A Stahl, Knut Möller, Josef Guttmann.   

Abstract

Rapid airway occlusions during mechanical ventilation are followed immediately by high-frequency pressure oscillations. To answer the question if the frequency of forced pressure oscillations is an indicator for partial obstruction of the endotracheal tube (ETT) we performed mathematical simulations and studies in a ventilated physical lung model. Model-derived predictions were evaluated in seven healthy volunteers. Partial ETT obstruction was mimicked by decreasing the inner diameter (ID) of the ETT. In the physical model ETTs of different ID were used. In spontaneously breathing volunteers viscous fluid was applied into the ETT's lumen. According to the predictions derived from mathematical simulations, narrowing of the ETT's ID from 9.0 to 7.0mm decreased the frequency of the pressure oscillations by 11% while changes of the respiratory system's compliance had no effect. In volunteers, a similar reduction (10.9%) was found when 5 ml fluid were applied. We conclude that analysis of pressure oscillations after flow interruption offers a tool for non-invasive detection of partial ETT obstruction.

Entities:  

Mesh:

Year:  2006        PMID: 16861058     DOI: 10.1016/j.resp.2006.05.010

Source DB:  PubMed          Journal:  Respir Physiol Neurobiol        ISSN: 1569-9048            Impact factor:   1.931


  6 in total

1.  Sound level analysis in endotracheal tube obstruction in spontaneous breathing and mechanical ventilation-an animal model study.

Authors:  Behzad Maghsoodi; Golnar Sabetian; Aram Azimi; Nader Tanideh; Alireza Mehdizade
Journal:  J Clin Monit Comput       Date:  2016-12-26       Impact factor: 2.502

2.  Tracheal pressure and endotracheal tube obstruction can be detected by continuous cuff pressure monitoring: in vitro pilot study.

Authors:  Shai Efrati; Israel Deutsch; Gabriel M Gurman; Matitiau Noff; Giorgio Conti
Journal:  Intensive Care Med       Date:  2010-03-16       Impact factor: 17.440

3.  [Acute obstruction of the endotracheal tube].

Authors:  D Steinmann; H-J Priebe; J Guttmann
Journal:  Anaesthesist       Date:  2008-03       Impact factor: 1.041

4.  Sound analysis in an in vitro endotracheal tube model.

Authors:  Young Sik Park; Young Wook Kee; Kwang Suk Park; Jinwoo Lee; Sang-Min Lee; Jae-Joon Yim; Chul-Gyu Yoo; Young Whan Kim; Sung Koo Han; Seok-Chul Yang
Journal:  Korean J Intern Med       Date:  2011-11-28       Impact factor: 2.884

5.  Ex Vivo Evaluation of Secretion-Clearing Device in Reducing Airway Resistance within Endotracheal Tubes.

Authors:  Christopher Waters; R Constance Wiener; Hamed M Motlagh
Journal:  Crit Care Res Pract       Date:  2018-12-10

6.  Pressure-dependent stress relaxation in acute respiratory distress syndrome and healthy lungs: an investigation based on a viscoelastic model.

Authors:  Steven Ganzert; Knut Möller; Daniel Steinmann; Stefan Schumann; Josef Guttmann
Journal:  Crit Care       Date:  2009-12-09       Impact factor: 9.097

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.