Literature DB >> 16856821

Four chamber view plus three-vessel and trachea view for a complete evaluation of the fetal heart during the second trimester.

Antongiulio Del Bianco1, Salvatore Russo, Nicola Lacerenza, Matteo Rinaldi, Giuseppe Rinaldi, Luigi Nappi, Pantaleo Greco.   

Abstract

OBJECTIVE: To test the efficacy of a recently introduced ultrasonic scanning plane (three vessel and trachea view -3VTV- plus color flow mapping -3VTVC) on a low-risk population for detection of congenital heart disease (CHD). PATIENTS AND
SETTING: Antenatal clinic dealing with local low-risk population. All antenatal patients having a second trimester scan in a 1 year period. All patients had a 3VT plus 3VTC views added to routine four chamber view. Postnatal examinations were performed according to standard hospital protocol.
RESULTS: 2847 patients were examined. The plane was achievable in all 23 fetuses with CHD detected, three false negative (aortic coarctation) and two false positive. Sensitivity of the examination was 88.5%, as high as more sophisticated and difficult targeted cardiac scanning. The extra time necessary to perform the test was minimal.
CONCLUSION: 3VTV and 3VTCV were satisfactory used as imaging planes in a busy antenatal clinic in a low-risk population. They could be easily added to the four chamber view as routine screening for CHD and increase the detection rate to 90%.

Entities:  

Mesh:

Year:  2006        PMID: 16856821     DOI: 10.1515/JPM.2006.059

Source DB:  PubMed          Journal:  J Perinat Med        ISSN: 0300-5577            Impact factor:   1.901


  11 in total

1.  Prenatal Detection of Congenital Heart Diseases Using Echocardiography: 12-Year Results of an Improving Program With 9782 Cases.

Authors:  Yanqiu Ou; Michael S Bloom; Jinzhuang Mai; Melissa Francois; Wei Pan; Xiaohua Xiao; Ximeng Wang; Zhiqiang Nie; Yanji Qu; Xiangmin Gao; Yong Wu; Xiaoqing Liu; Jian Zhuang; Jimei Chen
Journal:  Front Public Health       Date:  2022-05-13

2.  A step-wise approach for analysis of the mouse embryonic heart using 17.6Tesla MRI.

Authors:  Rinat Gabbay-Benziv; E Albert Reece; Fang Wang; Amnon Bar-Shir; Chris Harman; Ozhan M Turan; Peixin Yang; Sifa Turan
Journal:  Magn Reson Imaging       Date:  2016-08-26       Impact factor: 2.546

3.  Routine use of color Doppler in fetal heart scanning in a low-risk population.

Authors:  Torbjørn Moe Eggebø; Claudia Heien; Magne Berget; Christian Lycke Ellingsen
Journal:  ISRN Obstet Gynecol       Date:  2012-05-20

4.  Color and power Doppler combined with Fetal Intelligent Navigation Echocardiography (FINE) to evaluate the fetal heart.

Authors:  L Yeo; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2017-08-14       Impact factor: 7.299

5.  Brazilian Fetal Cardiology Guidelines - 2019.

Authors:  Simone R F Fontes Pedra; Paulo Zielinsky; Cristiane Nogueira Binotto; Cristiane Nunes Martins; Eduardo Sérgio Valério Borges da Fonseca; Isabel Cristina Britto Guimarães; Izabele Vian da Silveira Corrêa; Karla Luiza Matos Pedrosa; Lilian Maria Lopes; Luiz Henrique Soares Nicoloso; Marcia Ferreira Alves Barberato; Marina Maccagnano Zamith
Journal:  Arq Bras Cardiol       Date:  2019-06-06       Impact factor: 2.000

6.  Performance of different scan protocols of fetal echocardiography in the diagnosis of fetal congenital heart disease: a systematic review and meta-analysis.

Authors:  Yifei Li; Yimin Hua; Jie Fang; Chuan Wang; Lina Qiao; Chaomin Wan; Dezhi Mu; Kaiyu Zhou
Journal:  PLoS One       Date:  2013-06-04       Impact factor: 3.240

7.  Impact of a standardized training program on midwives' ability to assess fetal heart anatomy by ultrasound.

Authors:  Eric Hildebrand; Madeleine Abrandt Dahlgren; Catarina Sved; Tomas Gottvall; Marie Blomberg; Birgitta Janerot-Sjoberg
Journal:  BMC Med Imaging       Date:  2014-06-02       Impact factor: 1.930

8.  Novel foetal echocardiographic image processing software (5D Heart) improves the display of key diagnostic elements in foetal echocardiography.

Authors:  Wan-Yu Hu; Jin-Hong Zhou; Xiao-Ying Tao; Shi-Yan Li; Bei Wang; Bo-Wen Zhao
Journal:  BMC Med Imaging       Date:  2020-04-03       Impact factor: 1.930

9.  Cardiac axis evaluation as a screening method for detecting cardiac abnormalities in the first trimester of pregnancy.

Authors:  Florina Nela Oşvar; Adrian Claudiu Raţiu; Florica Voiţă-Mekereş; Gheorghe Florin Voiţă; Mihaela Gabriela Bonţea; Mariana Racoviţă; Gabriel Mihai Mekereş; Florian Dorel Bodog
Journal:  Rom J Morphol Embryol       Date:  2020       Impact factor: 1.033

Review 10.  Diagnostic Value of Fetal Echocardiography for Congenital Heart Disease: A Systematic Review and Meta-Analysis.

Authors:  Ya-Fei Zhang; Xian-Ling Zeng; En-Fa Zhao; Hong-Wei Lu
Journal:  Medicine (Baltimore)       Date:  2015-10       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.