Literature DB >> 16843174

Effectiveness and safety of sirolimus stent implantation for coronary in-stent restenosis: the TRUE (Tuscany Registry of Sirolimus for Unselected In-Stent Restenosis) Registry.

Francesco Liistro1, Massimo Fineschi, Paolo Angioli, Giuseppe Sinicropi, Giovanni Falsini, Tommaso Gori, Kenneth Ducci, Achille Bravi, Leonardo Bolognese.   

Abstract

OBJECTIVES: This study sought to evaluate the effectiveness and safety of the sirolimus-eluting stent in the treatment of in-stent restenosis (ISR) in consecutive unselected patients undergoing coronary intervention in a real-world scenario.
BACKGROUND: Restenosis after bare metal stenting is characterized by a high rate of re-restenosis once treated with repeated percutaneous coronary intervention.
METHODS: The study was designed as a prospective two-center registry. We enrolled 244 patients with ISR in a native coronary artery or saphenous vein graft who had clinical indication for repeat intervention.
RESULTS: Sirolimus stent implantation was successful in all lesions. At 9-month follow-up, death occurred in 4 (1.6%) patients, myocardial infarction in 4 (1.6%), and ischemia-driven target lesion revascularization (TLR) in 12 (4.9%), for a cumulative event-free survival of 227 (93%). Although 9-month follow-up angiography was planned in all patients, only 150 (62%) patients completed it, and restenosis was present in 13 (8.7%) patients. Diabetes and non-ST-segment elevation acute coronary syndrome at presentation were the only independent predictors of freedom from ischemia-driven TLR and major adverse cardiac events.
CONCLUSIONS: Sirolimus stent implantation for the treatment of ISR is effective and safe. In diabetic patients and in those with acute coronary syndrome, the higher rate of recurrence requires further evaluation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16843174     DOI: 10.1016/j.jacc.2006.03.039

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  7 in total

1.  On-label and off-label use of drug-eluting stents: comparison of short- and long-term outcomes.

Authors:  Hamidreza Poorhosseini; Seyed Ebrahim Kassaian; Hasan Aghajani; Mohammad Alidoosti; Ali Mohammad Hajizeinali; Mojtaba Salarifar; Ebrahim Nematipour; Ali Reza Amirzadegan; Mahmood Sheikhfathollahi; Nahid Shafiee; Elham Hakki-Kazazi; Masoumeh Lotfi Tokaldany
Journal:  Tex Heart Inst J       Date:  2012

2.  Treatment of in-stent restenosis with sirolimus-eluting-stents: results from the prospective German Cypher stent registry.

Authors:  Helge Möllmann; Albrecht Elsässer; Holger Nef; Steffen Schneider; Christoph A Nienaber; Gert Richardt; Michael Weber; Malte Kelm; Benny Levenson; Tassilo Bonzel; Ulrich Tebbe; Georg Sabin; Thomas Pfannebecker; Jochen Senges; Christian W Hamm
Journal:  Clin Res Cardiol       Date:  2008-03-03       Impact factor: 5.460

3.  Very late thrombosis in a bare metal stent: an under-recognized problem.

Authors:  Massimo Fineschi; Tommaso Gori
Journal:  Can J Cardiol       Date:  2008-02       Impact factor: 5.223

4.  Efficacy and safety of drug-eluting stent implantation for the treatment of in-stent restenosis occurring within bare-metal stent and drug-eluting stent.

Authors:  Heng Ge; Qing Zhang; Wei Zhou; Qing He; Zhi-hua Han; Ben He
Journal:  J Zhejiang Univ Sci B       Date:  2010-08       Impact factor: 3.066

5.  Application of response surface methodology in development of sirolimus liposomes prepared by thin film hydration technique.

Authors:  Saeed Ghanbarzadeh; Hadi Valizadeh; Parvin Zakeri-Milani
Journal:  Bioimpacts       Date:  2013-04-30

6.  Therapeutic strategy for in-stent restenosis based on the restenosis pattern after drug-eluting stent implantation.

Authors:  Ki-Hun Kim; Doo-Il Kim; Il-Hwan Kim; Jong-Yoon Kim; Yang-Chun Han; Sang-Hoon Seol; Ung Kim; Tae-Hyun Yang; Dae-Kyeong Kim; Dong-Soo Kim; Sang-Hee Lee; Jong-Seon Park; Young-Jo Kim; Dong-Gu Shin; Yoon-Kyung Cho; Chang-Wook Nam; Seung-Ho Hur; Kwon-Bae Kim
Journal:  Korean Circ J       Date:  2009-10-28       Impact factor: 3.243

7.  Serial changes of neointimal tissue after everolimus-eluting stent implantation in porcine coronary artery: an optical coherence tomography analysis.

Authors:  Hoyoun Won; Jung-Sun Kim; Dong-Ho Shin; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Biomed Res Int       Date:  2014-09-18       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.