Literature DB >> 16841920

Integrated preconcentration SDS-PAGE of proteins in microchips using photopatterned cross-linked polyacrylamide gels.

Anson V Hatch1, Amy E Herr, Daniel J Throckmorton, James S Brennan, Anup K Singh.   

Abstract

The potential of integration of functions in microfluidic chips is demonstrated by implementing on-chip preconcentration of proteins prior to on-chip protein sizing by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Two polymeric elements-a thin (approximately 50 microm) size exclusion membrane for preconcentration and a longer (approximately cm) porous monolith for protein sizing-were fabricated in situ using photopolymerization. Contiguous placement of the two polymeric elements in the channels of a microchip enabled simple and zero dead volume integration of the preconcentration with SDS-PAGE. The size exclusion membrane was polymerized in the injection channel using a shaped laser beam, and the sizing monolith was cast by photolithography using a mask and UV lamp. Proteins injected electrophoretically were trapped on the upstream side of the size exclusion membrane (MW cutoff approximately 10 kDa) and eluted off the membrane by reversing the electric field. Subsequently, the concentrated proteins were separated in a cross-linked polyacrylamide monolith that was patterned contiguous to the size exclusion membrane. The extent of protein preconcentration is easily tuned by varying the voltage during injection or by controlling the sample volume loaded. Electric fields applied across the nanoporous membrane resulted in a concentration polarization effect evidenced by decreasing current over time and irreproducible migration of proteins during sizing. To minimize the concentration polarization effect, sieving gels were polymerized only on the separation side of the membrane, and an alternate electrical current path was employed, bypassing the membrane, for most of the elution and separation steps. Electrophoretically sweeping a fixed sample volume against the membrane yields preconcentration factors that are independent of protein mobility. The volume sweeping method also avoids biased protein loading from concentration polarization and sample matrix variations. Mobilities of the concentrated proteins were log-linear with respect to molecular weight, demonstrating the suitability of this approach for protein sizing. Proteins were concentrated rapidly (<5 min) over 1000-fold followed by high-resolution separation in the sieving monolith. Proteins with concentrations as low as 50 fM were detectable with 30 min of preconcentration time. The integrated preconcentration-sizing approach facilitates analysis of low-abundant proteins that cannot be otherwise detected. Moreover, the integrated preconcentration-analysis approach employing in situ formation of photopatterned polymeric elements provides a generic, inexpensive, and versatile method to integrate functions at chip level and can be extended to lowering of detection limits for other applications such as DNA analysis and clinical diagnostics.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16841920     DOI: 10.1021/ac0600454

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  22 in total

Review 1.  Protein separation by capillary gel electrophoresis: a review.

Authors:  Zaifang Zhu; Joann J Lu; Shaorong Liu
Journal:  Anal Chim Acta       Date:  2011-10-19       Impact factor: 6.558

2.  Automated microfluidic protein immunoblotting.

Authors:  Mei He; Amy E Herr
Journal:  Nat Protoc       Date:  2010-10-28       Impact factor: 13.491

Review 3.  Integrated microfluidic platform for oral diagnostics.

Authors:  Amy E Herr; Anson V Hatch; William V Giannobile; Daniel J Throckmorton; Huu M Tran; James S Brennan; Anup K Singh
Journal:  Ann N Y Acad Sci       Date:  2007-03       Impact factor: 5.691

4.  Long-range and superfast trapping of DNA molecules in an ac electrokinetic funnel.

Authors:  Jiong-Rong Du; Yi-Je Juang; Jie-Tang Wu; Hsien-Hung Wei
Journal:  Biomicrofluidics       Date:  2008-12-05       Impact factor: 2.800

5.  Multiplexed proteomic sample preconcentration device using surface-patterned ion-selective membrane.

Authors:  Jeong Hoon Lee; Yong-Ak Song; Jongyoon Han
Journal:  Lab Chip       Date:  2008-03-04       Impact factor: 6.799

6.  Preconcentration of diluted mixed-species samples following separation and collection in a micro-nanofluidic device.

Authors:  Yi-Ying Chen; Ping-Hsien Chiu; Chen-Hsun Weng; Ruey-Jen Yang
Journal:  Biomicrofluidics       Date:  2016-02-18       Impact factor: 2.800

7.  Homogeneous immunosubtraction integrated with sample preparation enabled by a microfluidic format.

Authors:  Akwasi A Apori; Amy E Herr
Journal:  Anal Chem       Date:  2011-03-04       Impact factor: 6.986

8.  Nanofluidic device for continuous multiparameter quality assurance of biologics.

Authors:  Sung Hee Ko; Divya Chandra; Wei Ouyang; Taehong Kwon; Pankaj Karande; Jongyoon Han
Journal:  Nat Nanotechnol       Date:  2017-05-22       Impact factor: 39.213

Review 9.  Advances in microfluidic materials, functions, integration, and applications.

Authors:  Pamela N Nge; Chad I Rogers; Adam T Woolley
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

10.  Use of photopatterned porous polymer monoliths as passive micromixers to enhance mixing efficiency for on-chip labeling reactions.

Authors:  Dieudonne A Mair; Thomas R Schwei; Theresa S Dinio; Frantisek Svec; Jean M J Fréchet
Journal:  Lab Chip       Date:  2009-01-07       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.