Literature DB >> 16840859

Evaluation of decision rules for frequency-doubling technology screening tests.

Stuart K Gardiner1, Douglas R Anderson, Murray Fingeret, John J McSoley, Chris A Johnson.   

Abstract

PURPOSE: Frequency-doubling technology (FDT) perimetry has shown promise as a screening test for glaucoma. This study investigates different possible decision rules for FDT screening by applying them to groups of normal and glaucoma subjects.
METHODS: Within three centers, 218 subjects (aged 15-88 years; 78 with glaucoma, 140 without ocular disease) were each tested twice with the screening program of the FDT perimeter. The subjects consisted of 140 normal subjects with no evidence of glaucoma or other ocular disease likely to affect the visual field and 78 subjects with a diagnosis of glaucoma and no other ocular disease. Fifteen decision rules were applied to the data to compare their sensitivity and specificity.
RESULTS: Estimated specificities of the different decision rules ranged from 78% to 99%, although with this sample size, the confidence intervals for these estimates are quite large. Estimated sensitivities ranged from 40% to 72%. Suggested criteria for distinguishing normal subjects from those with glaucoma seem to be either a cluster of two or more adjacent locations abnormal at the p < 2% level with at least one location confirmed or a single location very abnormal (p < 1%) and confirmed.
CONCLUSIONS: Specificity was clearly improved by confirming an apparently abnormal test result by repeating the screening test outweighing the resultant small loss in sensitivity. These findings provide useful information for making an informed choice of decision rules for FDT screening results.

Entities:  

Mesh:

Year:  2006        PMID: 16840859     DOI: 10.1097/01.opx.0000225912.06027.ac

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  3 in total

1.  Comparison of different methods of inter-eye asymmetry of rim area and disc area analysis.

Authors:  A A K Fansi; H Boisjoly; M Chagnon; P J Harasymowycz
Journal:  Eye (Lond)       Date:  2011-09-16       Impact factor: 3.775

2.  Using frequency-doubling perimetry to detect optic neuropathy in patients with Graves' orbitopathy.

Authors:  Mário L R Monteiro; André L F Portes; Frederico C Moura; Dina B W Regensteiner
Journal:  Jpn J Ophthalmol       Date:  2008-12-17       Impact factor: 2.447

3.  Visual function-specific perimetry to identify glaucomatous visual loss using three different definitions of visual field abnormality.

Authors:  Ali Tafreshi; Pamela A Sample; Jeffrey M Liebmann; Christopher A Girkin; Linda M Zangwill; Robert N Weinreb; Maziar Lalezary; Lyne Racette
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-10-31       Impact factor: 4.799

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.