Literature DB >> 16839735

Immunomagnetic beads assay for the detection of botulinum neurotoxin types C and D.

Frank Gessler1, Katrin Hampe, Michaela Schmidt, Helge Böhnel.   

Abstract

An immunomagnetic beads assay for the simultaneous quantification of botulinum neurotoxin types C and D was developed. Specific monoclonal antibodies against the heavy chain of the toxin and affinity-purified biotinylated polyclonal antibodies (pAbs) were used. The antibodies were preincubated with the sample. The complex being formed was then captured by magnetic beads coated with antimouse IgG. Streptavidin-poly-horseradish peroxidase, a signal amplifier, bound to the biotinylated pAb. A maximum sensitivity of approximately 0.3 minimal lethal doses for mice per milliliter was achieved with culture supernatants of both toxin types.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16839735     DOI: 10.1016/j.diagmicrobio.2006.04.014

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  10 in total

1.  Evaluation of an IgY-based immunomagnetic enzyme-linked immunosorbent assay system for detection of circulating Schistosoma japonicum antigen in serum samples from patients in China.

Authors:  Jia-hui Lei; Bing-tao Su; Hong Xu; Ji-long Shen; Xiao-hong Guan; Zhen-qing Feng; Yong-long Li; Ming-xing Xu; Wen-qi Liu
Journal:  Am J Trop Med Hyg       Date:  2011-12       Impact factor: 2.345

2.  Llama-derived single-domain antibodies for the detection of botulinum A neurotoxin.

Authors:  Marla D Swain; George P Anderson; Dan Zabetakis; Rachael D Bernstein; Jinny L Liu; Laura J Sherwood; Andrew Hayhurst; Ellen R Goldman
Journal:  Anal Bioanal Chem       Date:  2010-06-28       Impact factor: 4.142

3.  A fluorescence detection platform using spatial electroluminescent excitation for measuring botulinum neurotoxin A activity.

Authors:  Kim E Sapsford; Steven Sun; Jesse Francis; Shashi Sharma; Yordan Kostov; Avraham Rasooly
Journal:  Biosens Bioelectron       Date:  2008-06-18       Impact factor: 10.618

4.  Simultaneous and sensitive detection of six serotypes of botulinum neurotoxin using enzyme-linked immunosorbent assay-based protein antibody microarrays.

Authors:  Yanfeng Zhang; Jianlong Lou; Kathy L Jenko; James D Marks; Susan M Varnum
Journal:  Anal Biochem       Date:  2012-08-27       Impact factor: 3.365

5.  Multi-wavelength Spatial LED illumination based detector for in vitro detection of Botulinum Neurotoxin A Activity.

Authors:  Steven Sun; Jesse Francis; Kim E Sapsford; Yordan Kostov; Avraham Rasooly
Journal:  Sens Actuators B Chem       Date:  2010-04-08       Impact factor: 7.460

6.  Lab-on-a-chip for botulinum neurotoxin a (BoNT-A) activity analysis.

Authors:  Steven Sun; Miguel Ossandon; Yordan Kostov; Avraham Rasooly
Journal:  Lab Chip       Date:  2009-09-17       Impact factor: 6.799

7.  Quantum dot immunoassays in renewable surface column and 96-well plate formats for the fluorescence detection of botulinum neurotoxin using high-affinity antibodies.

Authors:  Marvin G Warner; Jay W Grate; Abby Tyler; Richard M Ozanich; Keith D Miller; Jianlong Lou; James D Marks; Cynthia J Bruckner-Lea
Journal:  Biosens Bioelectron       Date:  2009-06-26       Impact factor: 10.618

8.  In vivo neutralization of botulinum neurotoxins serotype E with heavy-chain camelid antibodies (VHH).

Authors:  Hamid Bakherad; Seyed Latif Mousavi Gargari; Iraj Rasooli; Masoumeh Rajabibazl; Mohammad Mohammadi; Walead Ebrahimizadeh; Leila Safaee Ardakani; Hamed Zare
Journal:  Mol Biotechnol       Date:  2013-10       Impact factor: 2.695

9.  Studies in the use of magnetic microspheres for immunoaffinity extraction of paralytic shellfish poisoning toxins from shellfish.

Authors:  Raymond Devlin; Katrina Campbell; Kentaro Kawatsu; Christopher Elliott
Journal:  Toxins (Basel)       Date:  2011-01-04       Impact factor: 4.546

10.  Detection of Clonorchis sinensis circulating antigen in sera from Chinese patients by immunomagnetic bead ELISA based on IgY.

Authors:  Ge Nie; Ting Wang; Shengjun Lu; Wenqi Liu; Yonglong Li; Jiahui Lei
Journal:  PLoS One       Date:  2014-12-04       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.