Literature DB >> 1683418

Ultrasonographic velocimetry of the fetal ductus venosus.

T Kiserud1, S H Eik-Nes, H G Blaas, L R Hellevik.   

Abstract

In fetal lambs, the ductus venosus shunts well-oxygenated blood directly to the heart, a pattern expected to be found also in the human fetus. We aimed to describe the human ductus venosus in a longitudinal sonographic study of two-dimensional imaging, colour flow mapping, and pulsed doppler velocimetry every 3-4 weeks during the second half of pregnancy. The fetuses of 29 healthy women were studied. The ductus venosus and its blood flow were identified and recorded for later analysis that included maximum velocity tracing. In the 184 examinations analysed, the ductus venosus appeared as a narrow vessel projecting a high-velocity jet posteriorly to reach the foramen ovale. The mean peak velocity in the ductus venosus increased from 65 cm/s in week 18 to 75 cm/s at term. Low values of the time-averaged maximum velocity were found in 2 fetuses with cardiovascular abnormalities (1 supraventricular tachycardia, 1 congestive heart failure), as a result of reversed flow in the ductus venosus during atrial systole. The high peak velocity in the ductus venosus, which is comparable with arterial velocities, probably gives the blood sufficient momentum to reach the foramen ovale without extensive mixing with deoxygenated blood. Velocimetry of the ductus venosus carries new diagnostic possibilities.

Entities:  

Mesh:

Year:  1991        PMID: 1683418     DOI: 10.1016/0140-6736(91)92720-m

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  14 in total

1.  Mechanical properties of the fetal ductus venosus and umbilical vein.

Authors:  L R Hellevik; T Kiserud; F Irgens; N Stergiopulos; M Hanson
Journal:  Heart Vessels       Date:  1998       Impact factor: 2.037

Review 2.  Fetal cardiovascular physiology.

Authors:  J Rychik
Journal:  Pediatr Cardiol       Date:  2004 May-Jun       Impact factor: 1.655

3.  Ultrasonographic study of ductus venosus in healthy neonates.

Authors:  D Fugelseth; R Lindemann; K Liestøl; T Kiserud; A Langslet
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1997-09       Impact factor: 5.747

4.  Doppler velocimetry of ductus venous in preterm fetuses with brain sparing effect: neonatal outcome.

Authors:  Ynesmara Coelho Cosmo; Edward Araujo Júnior; Renato Augusto Moreira de Sá; Paulo Roberto Nassar de Carvalho; Rosiane Mattar; Laudelino Marques Lopes; Luciano Marcondes Machado Nardozza; Eduardo de Souza; Antonio Fernandes Moron
Journal:  J Prenat Med       Date:  2012-07

5.  Establishment of reference ranges for ductus venosus waveform indices in the Japanese population.

Authors:  Yasuhiro Takahashi; Keisuke Ishii; Keisuke Honda; Akira Kikuchi; Koichi Takakuwa; Kenichi Tanaka
Journal:  J Med Ultrason (2001)       Date:  2010-07-03       Impact factor: 1.314

Review 6.  The control of the ductus venosus: an update.

Authors:  F Coceani
Journal:  Eur J Pediatr       Date:  1993-12       Impact factor: 3.183

7.  Can the ductus venosus doppler predict the hemoglobinopathies?

Authors:  Atilla Karateke; Dilek Benk Silfeler; Arif Güngören; Raziye Keskin Kurt; Ayşe Güler Okyay; Recep Dokuyucu; Turker Ulutas; Burak Un; Hacer Paksoy; Ali Ulvi Hakverdi
Journal:  Int J Clin Exp Med       Date:  2015-03-15

8.  Intracardiac pressures in the human fetus.

Authors:  P Johnson; D J Maxwell; M J Tynan; L D Allan
Journal:  Heart       Date:  2000-07       Impact factor: 5.994

9.  Fetal liver blood flow distribution: role in human developmental strategy to prioritize fat deposition versus brain development.

Authors:  Keith M Godfrey; Guttorm Haugen; Torvid Kiserud; Hazel M Inskip; Cyrus Cooper; Nicholas C W Harvey; Sarah R Crozier; Sian M Robinson; Lucy Davies; Mark A Hanson
Journal:  PLoS One       Date:  2012-08-22       Impact factor: 3.240

10.  Fetal intervention in right outflow tract obstructive disease: selection of candidates and results.

Authors:  E Gómez Montes; I Herraiz; A Mendoza; A Galindo
Journal:  Cardiol Res Pract       Date:  2012-08-15       Impact factor: 1.866

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.