A rapid, sensitive and selective method based on LC-MS/MS has been developed for the direct determination of acrylamide residues in water in compliance with the current European Union (EU) 98/83 Drinking Water Directive. Given the high polarity of acrylamide, the application of a rapid on-line solid phase extraction step, commonly used for preconcentrating low analyte levels, was not found to be completely satisfactory. Therefore, an alternative approach based on the use of direct large-volume injection into the LC-MS/MS system has been used. Three atmospheric-pressure interfaces (ESI, APCI and Ion Sabre APCI) were checked to reach the required sensitivity (0.1 microg/l). All three interfaces were tested by analysis of six different water samples (surface water, groundwater, drinking water and three treated water samples) spiked at three concentration levels each (0.1, 1 and 10 microg/l). When using ESI, poor sensitivity and high matrix effects were observed. This situation improved when APCI was used as the interface because no matrix effect was found, although sensitivity was not completely satisfactory. The best results were obtained by interfacing the Ion Sabre APCI; its higher sensitivity for acrylamide (LOD 0.03 microg/l) and the absence of matrix effects recommended its selection. Using this approach, satisfactory recoveries (90-97%) and precision (<12%) were obtained for all water samples studied. Besides, the acquisition of two different MS/MS transitions allowed not only the quantification but also the confirmation of acrylamide in water at concentration levels around 0.1 microg/l. Copyright 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16832838     DOI: 10.1002/jms.1063

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  3 in total

1.  Direct injection method for HPLC/MS/MS analysis of acrylamide in aqueous solutions: application to adsorption experiments.

Authors:  Ines Mnif; Charlotte Hurel; Nicolas Marmier
Journal:  Environ Sci Pollut Res Int       Date:  2014-11-13       Impact factor: 4.223

2.  A sensitive analytical procedure for monitoring acrylamide in environmental water samples by offline SPE-UPLC/MS/MS.

Authors:  Anne Togola; Charlotte Coureau; Anne-Gwenaëlle Guezennec; Solène Touzé
Journal:  Environ Sci Pollut Res Int       Date:  2014-12-04       Impact factor: 4.223

3.  N-(β-Carb-oxy-eth-yl)-α-isoleucine.

Authors:  Irene Nehls; Olaf Hanebeck; Roland Becker; Franziska Emmerling
Journal:  Acta Crystallogr Sect E Struct Rep Online       Date:  2013-01-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.