Literature DB >> 16829672

Correlation and agreement between bispectral index and state entropy of the electroencephalogram during propofol anaesthesia.

V Bonhomme1, E Deflandre, P Hans.   

Abstract

BACKGROUND: Bispectral index (BIS) and state entropy (SE) monitor hypnosis. We evaluated the correlation and the agreement between those parameters during propofol anaesthesia and laryngoscopy with and without muscle relaxation.
METHODS: A total of 25 patients were anaesthetized with propofol. At steady state (SS: BIS 40-50), they randomly received rocuronium (R) or saline (S); 3 min thereafter, a 20 s laryngoscopy was performed. Correlation (regression analysis) and agreement (Bland-Altman analysis) were evaluated before induction (baseline), at loss of eyelash reflex (LER), at SS and during the first 3 min after laryngoscopy (L).
RESULTS: The correlation coefficient r (95% CI), the mean difference (MD) (95% CI), and the limits of agreement [lower-upper limits of 95% CI of MD (sd 1.96)] between BIS and SE were as follows. Overall recordings: 0.87 (0.83 to 0.90), 2.5 (1.2 to 3.0), and [-19.5 to 24.6]; Baseline: 0.45 (0.06 to 0.72), 7.6 (6.0 to 9.2), and [-2.7 to 17.9]; LER: 0.74 (0.47 to 0.88), 8.3 (3.5 to 13.2), and [-22.6 to 39.3]; SS, all patients: 0.41 (0.14 to 0.63), 2.0 (-0.5 to 4.6), and [-19.0 to 23.3]; SS, Group S: 0.36 (-0.07 to 0.68), 1.9 (-2.5 to 6.3), and [-25.0 to 28.8]; SS, Group R: 0.63 (0.32 to 0.82), 0.2 (-2.0 to 2.3), and [-14.0 to 14.4]; L, all patients: 0.49 (0.32 to 0.63), 0.7 (-1.6 to 3.0), and [-25.6 to 27.1]; L, Group S: 0.41 (0.13 to 0.63), 2.3 (-2.4 to 7.1), and [-36.7 to 41.3]; L, Group R: 0.72 (0.56 to 0.83), -0.6 (-2.2 to 1.0), and [-14.3 to 13.1]. The correlation was good except for SS in Group S. The MD was significantly different from 0 for overall recordings, during baseline and LER, but not for the other conditions. The agreement was poor except for baseline, and SS and L in Group R.
CONCLUSIONS: BIS and SE are globally well correlated. In contrast, agreement is poor as differences of more than 20 units are frequently observed, except for awake and paralysed patients.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16829672     DOI: 10.1093/bja/ael171

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  11 in total

1.  Comparison of spectral entropy and BIS VISTA™ monitor during general anesthesia for cardiac surgery.

Authors:  Tadeusz Musialowicz; Pasi Lahtinen; Otto Pitkänen; Jouni Kurola; Ilkka Parviainen
Journal:  J Clin Monit Comput       Date:  2011-04-22       Impact factor: 2.502

2.  Sevoflurane/propofol coadministration provides better recovery than sevoflurane in combined general/epidural anesthesia: a randomized clinical trial.

Authors:  Chao Liang; Ming Ding; Fang Du; Jing Cang; Zhanggang Xue
Journal:  J Anesth       Date:  2014-02-21       Impact factor: 2.078

3.  A clinical comparison of etomidate-lipuro, propofol and admixture at induction.

Authors:  Fatma Saricaoglu; Sennur Uzun; Oguzhan Arun; Funda Arun; Ulku Aypar
Journal:  Saudi J Anaesth       Date:  2011-01

4.  A clinical comparison of ketofol (ketamine and propofol admixture) versus propofol as an induction agent on quality of laryngeal mask airway insertion and hemodynamic stability in children.

Authors:  Gamal T Yousef; Khalid M Elsayed
Journal:  Anesth Essays Res       Date:  2013 May-Aug

5.  Effect of neuromuscular blockade reversal by pyridostigmine on spectral entropy values during recovery from desflurane anesthesia: a prospective, randomized, double-blind, controlled trial.

Authors:  Eugene Kim; Jae Hun Ryu; Sung Hye Byun
Journal:  Korean J Anesthesiol       Date:  2016-06-01

6.  How Bispectral Index Compares to Spectral Entropy of the EEG and A-line ARX Index in the Same Patient.

Authors:  Werner Tiefenthaler; Joshua Colvin; Bernhard Steger; Karl P Pfeiffer; Patrizia L Moser; Janette Walde; Ingo H Lorenz; Christian Kolbitsch
Journal:  Open Med (Wars)       Date:  2018-11-24

7.  Quantifying the depth of anesthesia based on brain activity signal modeling.

Authors:  Hyub Huh; Sang-Hyun Park; Joon Ho Yu; Jisu Hong; Mee Ju Lee; Jang Eun Cho; Choon Hak Lim; Hye Won Lee; Jun Beom Kim; Kyung-Sook Yang; Seung Zhoo Yoon
Journal:  Medicine (Baltimore)       Date:  2020-01       Impact factor: 1.889

Review 8.  Spectral entropy monitoring for adults and children undergoing general anaesthesia.

Authors:  Anjolie Chhabra; Rajeshwari Subramaniam; Anurag Srivastava; Hemanshu Prabhakar; Mani Kalaivani; Saloni Paranjape
Journal:  Cochrane Database Syst Rev       Date:  2016-03-14

Review 9.  Evolution of electroencephalogram signal analysis techniques during anesthesia.

Authors:  Mahmoud I Al-Kadi; Mamun Bin Ibne Reaz; Mohd Alauddin Mohd Ali
Journal:  Sensors (Basel)       Date:  2013-05-17       Impact factor: 3.576

10.  Reduction of the dimensionality of the EEG channels during scoliosis correction surgeries using a wavelet decomposition technique.

Authors:  Mahmoud I Al-Kadi; Mamun Bin Ibne Reaz; Mohd Alauddin Mohd Ali; Chian Yong Liu
Journal:  Sensors (Basel)       Date:  2014-07-21       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.