Literature DB >> 16827875

Sensitization following LVAD implantation using leucodepleted blood is not due to HLA antibodies.

H Newell1, J D Smith, P Rogers, E Birks, A J Danskine, R E Fawson, M L Rose.   

Abstract

Implantation of left ventricular assist devices (LVAD) is associated with HLA antibody sensitization. The objective of this study was to determine the specificity of antibodies produced by LVAD recipients using a combination of ELISA, Luminex and microcytotoxicity assays. Fifty-one LVAD patients were studied, from 44 to 838 days post-implantation. No patient developed HLA antibodies, although 24 produced IgG antibodies detectable in both ELISA and Luminex assays. These antibodies manifest as positive reactions with class I and class II wells of the ELISA and also blank wells. In Luminex assays, they produce high MFI readings with the negative control beads. Antibodies were detected 18 to 228 days after implantation. This reactivity was found to be directed against bovine serum albumin (BSA), commonly used to block non-specific binding in ELISA and Luminex assays; absorption of sera with BSA-coated beads completely abrogated reactivity in all solid phase assays, but did not eliminate anti-HLA antibodies in control sera. Ten of the 24 patients have proceeded to transplantation, with a 1-year graft survival of 69%. In conclusion, it appears that implantation of LVADS disrupts immunoregulatory pathways leading to production of anti-albumin antibodies. These can be misinterpreted as anti-HLA antibodies in solid phase assays.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16827875     DOI: 10.1111/j.1600-6143.2006.01342.x

Source DB:  PubMed          Journal:  Am J Transplant        ISSN: 1600-6135            Impact factor:   8.086


  5 in total

1.  Elimination of false-positive results in a luminex assay for pneumococcal antibodies.

Authors:  Jerry W Pickering; Matthew T Larson; Thomas B Martins; Susan S Copple; Harry R Hill
Journal:  Clin Vaccine Immunol       Date:  2009-11-18

2.  LVAD implant as a bridge to heart transplantation is associated with allosensitization as measured by single antigen bead assay.

Authors:  Nisha Shankar; Richard Daly; Jennifer Geske; Sudhir K Kushwaha; Michael Timmons; Lyle Joyce; John Stulak; Manish Gandhi; Walter Kremers; Soon Park; Naveen L Pereira
Journal:  Transplantation       Date:  2013-08-15       Impact factor: 4.939

3.  Ventricular assist device elicits serum natural IgG that correlates with the development of primary graft dysfunction following heart transplantation.

Authors:  Sarah B See; Kevin J Clerkin; Peter J Kennel; Feifan Zhang; Matthew P Weber; Kortney J Rogers; Debanjana Chatterjee; Elena R Vasilescu; George Vlad; Yoshifumi Naka; Susan W Restaino; Maryjane A Farr; Veli K Topkara; Paolo C Colombo; Donna M Mancini; P Christian Schulze; Bruce Levin; Emmanuel Zorn
Journal:  J Heart Lung Transplant       Date:  2017-03-24       Impact factor: 10.247

4.  Report from a consensus conference on the sensitized patient awaiting heart transplantation.

Authors:  Jon Kobashigawa; Mandeep Mehra; Lori West; Ronald Kerman; James George; Marlene Rose; Adriana Zeevi; Nancy Reinsmoen; Jignesh Patel; Elaine F Reed
Journal:  J Heart Lung Transplant       Date:  2009-03       Impact factor: 10.247

5.  Lack of significant de novo HLA allosensitization in ventricular assist device recipients transfused with leukoreduced, ABO identical blood products.

Authors:  Myra Coppage; Marc Baker; Lawrence Fialkow; Danielle Meehan; Kelly Gettings; Leway Chen; H Todd Massey; Neil Blumberg
Journal:  Hum Immunol       Date:  2009-03-09       Impact factor: 2.850

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.