Literature DB >> 16825961

S2 iliosacral screw fixation for disruptions of the posterior pelvic ring: a report of 49 cases.

Berton R Moed1, Benjamin L Geer.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate the clinical safety and efficacy of using S2 iliosacral screws for pelvic fracture fixation.
DESIGN: Retrospective analysis of a treatment protocol in a consecutive patient series.
SETTING: Level 1 trauma center. PATIENTS: Between 1996 and 2001, 49 patients were treated with S2 iliosacral screws. There were 9 bilateral injuries with a total of 53 S2 screws inserted. Patients ranged in age from 14 to 71 years. Follow-up averaged 19 months (range 6 months to 6 years). Preoperative and postoperative radiographic evaluation included anteroposterior, inlet and outlet pelvic x-rays and two-dimensional computerized tomography (CT) with 3-mm slice thickness. Candidates for S2 screw fixation required adequate space on CT, which was defined as a minimum of 1 cm between foramina on 3 sequential preoperative CT slices in conjunction with inadequate available space in S1. INTERVENTION: S2 iliosacral screw fixation of disruptions of the posterior pelvic ring. MAIN OUTCOME MEASUREMENTS: Intraoperative iatrogenic nerve root injuries, postoperative screw position, and maintenance of the fixation construct under physiologic load.
RESULTS: There were no intraoperative iatrogenic nerve injuries. However, postoperative loss of reduction requiring revision surgery occurred in 2 patients with osteopenia. One was associated with injury to the S1 nerve root, which had full return of function within 1 year. Satisfactory screw position was documented on postoperative CT in all cases.
CONCLUSIONS: S2 iliosacral screw fixation is a safe and effective technique. However, it should be used with caution in patients with suspected pelvic osteopenia. Furthermore, any S2 screw with questionable purchase should be removed and an alternative fixation method selected.

Entities:  

Mesh:

Year:  2006        PMID: 16825961     DOI: 10.1097/00005131-200607000-00002

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  28 in total

1.  [Bony sacroiliac corridor. A virtual volume model for the accurate insertion of transarticular screws].

Authors:  T Mendel; K Appelt; P Kuhn; N Suhm
Journal:  Unfallchirurg       Date:  2008-01       Impact factor: 1.000

2.  Treatment of posterior pelvic ring injuries with minimally invasive percutaneous plate osteosynthesis.

Authors:  Tang Hao; Yang Changwei; Zhang Qiulin
Journal:  Int Orthop       Date:  2009-04-08       Impact factor: 3.075

3.  Standalone percutaneous transiliac plating of vertically unstable sacral fractures: outcomes, complications, and recommendations.

Authors:  Mostafa A Ayoub; Hossam M Gad; Osama A Seleem
Journal:  Eur Spine J       Date:  2015-04-22       Impact factor: 3.134

4.  Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model.

Authors:  Tao Wu; Wei Chen; Xu Li; Qi Zhang; Hong-Zhi Lv; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

5.  Functional outcome of unstable pelvic ring injuries after iliosacral screw fixation: single versus two screw fixation.

Authors:  S A Khaled; O Soliman; M A Wahed
Journal:  Eur J Trauma Emerg Surg       Date:  2014-10-21       Impact factor: 3.693

6.  Transsacral Osseous Corridor Anatomy Is More Amenable To Screw Insertion In Males: A Biomorphometric Analysis of 280 Pelves.

Authors:  Florian Gras; Heiko Gottschling; Manuel Schröder; Ivan Marintschev; Gunther O Hofmann; Rainer Burgkart
Journal:  Clin Orthop Relat Res       Date:  2016-07-08       Impact factor: 4.176

7.  Posterior pelvic ring bone density with implications for percutaneous screw fixation.

Authors:  Jonathan G Eastman; Trevor J Shelton; Milton Lee Chip Routt; Mark R Adams
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-09-09

8.  Anatomical considerations of safe drilling corridor upper sacral segment screw insertion.

Authors:  Hassan Bagheri; Figen Govsa
Journal:  J Orthop       Date:  2019-05-03

9.  2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series.

Authors:  Florian Gras; Ivan Marintschev; Arne Wilharm; Kajetan Klos; Thomas Mückley; Gunther O Hofmann
Journal:  BMC Musculoskelet Disord       Date:  2010-07-07       Impact factor: 2.362

10.  Standardized posterior pelvic imaging: use of CT inlet and CT outlet for evaluation and management of pelvic ring injuries.

Authors:  Christopher M McAndrew; David J Merriman; Michael J Gardner; William M Ricci
Journal:  J Orthop Trauma       Date:  2014-12       Impact factor: 2.512

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.