Literature DB >> 16825731

Polymer gel dosimeters with reduced toxicity: a preliminary investigation of the NMR and optical dose-response using different monomers.

R J Senden1, P De Jean2, K B McAuley1, L J Schreiner2,3.   

Abstract

In this work, three new polymer gel dosimeter recipes were investigated that may be more suitable for widespread applications than polyacrylamide gel dosimeters, since the extremely toxic acrylamide has been replaced with the less harmful monomers N-isopropylacrylamide (NIPAM), diacetone acrylamide and N-vinylformamide. The new gel dosimeters studied contained gelatin (5 wt%), monomer (3 wt%), N,N'-methylene-bis-acrylamide crosslinker (3 wt%) and tetrakis (hydroxymethyl) phosphonium chloride antioxidant (10 mM). The NMR response (R2) of the dosimeters was analysed for conditions of varying dose, dose rate, time post-irradiation, and temperature during irradiation and scanning. It was shown that the dose-response behaviour of the NIPAM/Bis gel dosimeter is comparable to that of normoxic polyacrylamide gel (PAGAT) in terms of high dose-sensitivity and low dependence on dose rate and irradiation temperature, within the ranges considered. The dose-response (R2) of NIPAM/Bis appears to be linear over a greater dose range than the PAGAT gel dosimeter. The effects of time post-irradiation (temporal instability) and temperature during NMR scanning on the R2 response were more significant for NIPAM/Bis dosimeters. Diacetone acrylamide and N-vinylformamide gel dosimeters possessed considerably lower dose-sensitivities. The optical dose-response, measured in terms of the attenuation coefficient for each polymer gel dosimeter, showed potential for the use of optical imaging techniques in future studies.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16825731     DOI: 10.1088/0031-9155/51/14/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  25 in total

1.  Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry.

Authors:  J J Luci; H M Whitney; J C Gore
Journal:  Phys Med Biol       Date:  2007-04-23       Impact factor: 3.609

2.  Effect of substrate storage conditions on the stability of "Smart" films used for mammalian cell applications.

Authors:  Blake M Bluestein; Jamie A Reed; Heather E Canavan
Journal:  Appl Surf Sci       Date:  2016-09-01       Impact factor: 6.707

3.  Influencing Factors on Reproducibility and Stability of MRI NIPAM Polymer Gel Dosimeter.

Authors:  Farideh Pak; Alireza Farajollahi; Ali Movafaghi; Alireza Naseri
Journal:  Bioimpacts       Date:  2013-07-14

4.  Sensitivity calibration procedures in optical-CT scanning of BANG 3 polymer gel dosimeters.

Authors:  Y Xu; Cheng-Shie Wuu; Marek J Maryanski
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

Review 5.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

6.  Influence of magnesium chloride on the dose-response of polyacrylamide-type gel dosimeters.

Authors:  Shin-Ichiro Hayashi; Hiraku Kawamura; Shuji Usui; Takahiro Tominaga
Journal:  Radiol Phys Technol       Date:  2018-09-04

7.  Normoxic polymer gel dosimetry using less toxic monomer of N-isopropyl acrylamide and X-ray computed tomography for radiation therapy applications.

Authors:  Seyed-Mostafa Ghavami; Asghar Mesbahi; Ismaeel Pesianian; Abbas Shafaee; Mohammad-Reza Aliparasti
Journal:  Rep Pract Oncol Radiother       Date:  2010-11-04

8.  Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry.

Authors:  Asghar Mesbahi; Vahid Jafarzadeh; Nahideh Gharehaghaji
Journal:  Rep Pract Oncol Radiother       Date:  2012-04-17

9.  Improvement of sensitivity of X-ray CT reading method for polymer gel in radiation therapy.

Authors:  Negin Javaheri; Mehran Yarahmadi; Abdollah Refaei; Ali Aghamohammadi
Journal:  Rep Pract Oncol Radiother       Date:  2019-12-19

10.  Effect of composition interactions on the dose response of an N-isopropylacrylamide gel dosimeter.

Authors:  Yuan-Jen Chang; Bor-Tsung Hsieh
Journal:  PLoS One       Date:  2012-10-12       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.