Literature DB >> 16823776

Diffusion tensor imaging in evaluation of human skeletal muscle injury.

Tatiana Zaraiskaya1, Dinesh Kumbhare, Michael D Noseworthy.   

Abstract

PURPOSE: To explore the capability and reliability of diffusion tensor magnetic resonance imaging (DTI) in the evaluation of human skeletal muscle injury.
MATERIALS AND METHODS: DTI of four patients with gastrocnemius and soleus muscles injuries was compared to eight healthy controls. Imaging was performed using a GE 3.0T short-bore scanner. A diffusion-weighted 2D spin echo echo-planar imaging (EPI) pulse sequence optimized for skeletal muscle was used. From a series of axially acquired diffusion tensor images the diffusion tensor eigenparameters (eigenvalues and eigenvectors), fractional anisotropy (FA), and apparent diffusion coefficient (ADC) were calculated and compared for injured and healthy calf muscles. Two dimensional (2D) projection maps of the principal eigenvectors were plotted to visualize the healthy and pathologic muscle fiber architectures.
RESULTS: Clear differences in FA and ADC were observed in injured skeletal muscle, compared to healthy controls. Mean control FA was 0.23 +/- 0.02 for medial and lateral gastrocnemius (mg and lg) muscles, and 0.20 +/- 0.02 for soleus (sol) muscles. In all patients FA values were reduced compared to controls, to as low as 0.08 +/- 0.02. The ADC in controls ranged from 1.41 to 1.31 x 10(-9) m(2)/second, while in patients this was consistently higher. The 2D projection maps revealed muscle fiber disorder in injured calves, while in healthy controls the 2D projection maps show a well organized (ordered) fiber structure.
CONCLUSION: DTI is a suitable method to assess human calf muscle injury.

Entities:  

Mesh:

Year:  2006        PMID: 16823776     DOI: 10.1002/jmri.20651

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  65 in total

Review 1.  Advanced MRI Techniques for Muscle Imaging.

Authors:  Vivek Kalia; Doris G Leung; Darryl B Sneag; Filippo Del Grande; John A Carrino
Journal:  Semin Musculoskelet Radiol       Date:  2017-08-03       Impact factor: 1.777

2.  Advanced MRI of articular cartilage.

Authors:  Hillary J Braun; Garry E Gold
Journal:  Imaging Med       Date:  2011-10

3.  Diffusion property differences of the lower leg musculature between athletes and non-athletes using 1.5T MRI.

Authors:  Yoshikazu Okamoto; Shintaro Mori; Yuka Kujiraoka; Katsuhiro Nasu; Yuji Hirano; Manabu Minami
Journal:  MAGMA       Date:  2011-11-16       Impact factor: 2.310

4.  Pre- and post-operative diffusion tensor imaging of the median nerve in carpal tunnel syndrome.

Authors:  Jaana Hiltunen; Erika Kirveskari; Jussi Numminen; Nina Lindfors; Harry Göransson; Riitta Hari
Journal:  Eur Radiol       Date:  2012-02-09       Impact factor: 5.315

5.  Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor.

Authors:  F M Zijta; M Froeling; M P van der Paardt; M M E Lakeman; S Bipat; A D Montauban van Swijndregt; G J Strijkers; A J Nederveen; J Stoker
Journal:  Eur Radiol       Date:  2011-01-01       Impact factor: 5.315

6.  Diffusion Tensor MRI Assessment of Skeletal Muscle Architecture.

Authors:  Anneriet M Heemskerk; Bruce M Damon
Journal:  Curr Med Imaging Rev       Date:  2007

7.  Multi-parametric MR imaging of quadriceps musculature in the setting of clinical frailty syndrome.

Authors:  David M Melville; Jane Mohler; Mindy Fain; Amy E Muchna; Elizabeth Krupinski; Puneet Sharma; Mihra S Taljanovic
Journal:  Skeletal Radiol       Date:  2016-01-07       Impact factor: 2.199

8.  Quantitative diffusion tensor MRI-based fiber tracking of human skeletal muscle.

Authors:  Drew A Lansdown; Zhaohua Ding; Megan Wadington; Jennifer L Hornberger; Bruce M Damon
Journal:  J Appl Physiol (1985)       Date:  2007-04-19

9.  In vivo MR tractography of thigh muscles using diffusion imaging: initial results.

Authors:  J F Budzik; V Le Thuc; X Demondion; M Morel; D Chechin; A Cotten
Journal:  Eur Radiol       Date:  2007-07-17       Impact factor: 5.315

10.  Effects of image noise in muscle diffusion tensor (DT)-MRI assessed using numerical simulations.

Authors:  Bruce M Damon
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.