Comparison of posterior capsule opacification between fellow eyes with two types of acrylic intraocular lens.

K Hayashi1, M Yoshida, H Hayashi.   

Abstract

PURPOSE: To compare the degree of posterior capsule opacification (PCO) and visual function between fellow eyes that received two different types of hydrophobic acrylic intraocular lenses (IOLs).
METHODS: Forty-five patients underwent bilateral phacoemulsification and implantation of an Alcon AcrySof IOL (MA60AC) in one eye and an AMO Sensar IOL (AR40e) in the fellow eye. The PCO density value was measured using the Scheimpflug videophotography system at 1, 6, 12, and 24 months after surgery. The incidence of eyes that required a neodymium:YAG (Nd:YAG) laser capsulotomy, visual acuity, and contrast sensitivity with and without a glare source were also examined.
RESULTS: The mean PCO value did not show a significant increase in either the AcrySof MA60AC or Sensar AR40e IOL groups, and was similar between the two groups throughout the 24-month follow-up period. The incidence of Nd:YAG laser capsulotomy was also the same between the groups. No significant difference was found in mean visual acuity between the two IOL groups during the follow-up, and there was no significant difference in photopic or mesopic contrast visual acuity with and without a glare source at 1 and 24 months after surgery.
CONCLUSION: The degree of PCO in eyes with an AcrySof IOL are almost the same as that in eyes with a Sensar IOL, with the results that visual acuity and contrast sensitivity with and without glare are similar.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16823457     DOI: 10.1038/sj.eye.6702496

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  5 in total

Review 1.  [Scheimpflug photography for the examination of phakic intraocular lenses].

Authors:  M Baumeister
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

Review 2.  Biomaterial Influence on Intraocular Lens Performance: An Overview.

Authors:  Cari Pérez-Vives
Journal:  J Ophthalmol       Date:  2018-03-15       Impact factor: 1.909

Review 3.  An overview of the influence and design of biomaterial of the intraocular implant of the posterior capsule opacification.

Authors:  Razvan Vladimir Nanu; Emil Ungureanu; Sinziana Luminita Instrate; Alexandra Vrapciu; Roxana Cozubas; Laura Carstocea; Liliana Mary Voinea; Radu Ciuluvica
Journal:  Rom J Ophthalmol       Date:  2018 Jul-Sep

4.  Three-year incidence of Nd:YAG capsulotomy and posterior capsule opacification and its relationship to monofocal acrylic IOL biomaterial: a UK Real World Evidence study.

Authors:  Paul G Ursell; Mukesh Dhariwal; Katarina Majirska; Frank Ender; Shoshannah Kalson-Ray; Alessandra Venerus; Cristiana Miglio; Christine Bouchet
Journal:  Eye (Lond)       Date:  2018-06-11       Impact factor: 3.775

5.  A meta-analysis of Nd:YAG capsulotomy rates for two hydrophobic intraocular lens materials.

Authors:  Mark Von Tress; James S Marotta; Stephen S Lane; Ramesh Sarangapani
Journal:  Clin Ophthalmol       Date:  2018-06-22