Literature DB >> 16823298

Neuroform in-stent stenosis: incidence, natural history, and treatment strategies.

David Fiorella1, Felipe C Albuquerque, Henry Woo, Peter A Rasmussen, Thomas J Masaryk, Cameron G McDougall.   

Abstract

OBJECTIVE: Delayed in-stent stenosis is an important and well-characterized complication of angioplasty and stenting for the treatment of intra- and extracranial atheromatous disease. The current series describes the incidence and natural history of in-stent stenosis after the deployment of the Neuroform stent within the cerebrovasculature for the treatment of aneurysms.
METHODS: The collaborative Cleveland Clinic Foundation-Barrow Neurological Institute endovascular database was reviewed to identify cases of delayed moderate or severe in-stent stenosis observed during the follow-up of cerebral aneurysms treated with the Neuroform stent. The hospital charts, clinic records, and operative reports for these patients were reviewed.
RESULTS: Of a total of 156 patients with follow-up, nine (5.8%) cases of moderate or severe delayed (>2 mo) in-stent stenosis were identified, including two parent vessel occlusions. In two cases, patients presented 3 months after stent-supported aneurysm embolization with focal neurological symptoms. Both of these patients were treated with angioplasty. One eventually required surgical bypass. Of the seven asymptomatic patients, four demonstrated some degree of spontaneous resolution at follow-up, one progressed to complete occlusion, one is awaiting further follow-up, and one patient died of unrelated causes. Of the nine patients in the series, five were treated with "bioactive" coils (Matrix, Hydrocoil, Cerecyte), three were treated with bare platinum coils, and one was treated with stenting alone. The earliest time interval to diagnosis was 2.5 months and 3 months for asymptomatic and symptomatic patients, respectively. The earliest interval documented for spontaneous resolution was 9 months.
CONCLUSION: Delayed Neuroform in-stent stenosis, occurring in 5.8% of cases, is not a rare phenomenon. The stenosis can be symptomatic and may require endovascular treatment or surgical bypass. In asymptomatic patients, a strategy of "watchful waiting" may be effective because many patients demonstrate partial or complete resolution at follow-up. The spontaneous resolution of delayed in-stent stenosis has not been previously described. This may be a phenomenon unique to the application of low radial force, self-expanding stents within the nonatheromatous cerebrovasculature.

Entities:  

Mesh:

Year:  2006        PMID: 16823298     DOI: 10.1227/01.NEU.0000219853.56553.71

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  50 in total

1.  Frontiers of stent-assisted aneurysm coiling.

Authors:  Boris Lubicz
Journal:  Neuroradiology       Date:  2010-10-06       Impact factor: 2.804

2.  Treatment of intracranial aneurysms using flow-diverting silk stents (BALT): a single centre experience.

Authors:  M Leonardi; L Cirillo; F Toni; M Dall'olio; C Princiotta; A Stafa; L Simonetti; R Agati
Journal:  Interv Neuroradiol       Date:  2011-10-17       Impact factor: 1.610

Review 3.  Materials and techniques for coiling of cerebral aneurysms: how much scientific evidence do we have?

Authors:  W Kurre; J Berkefeld
Journal:  Neuroradiology       Date:  2008-09-19       Impact factor: 2.804

4.  Very late in-stent thrombosis 9 years after double stent treatment of fusiform basilar artery aneurysm.

Authors:  Robert Juszkat; Katarzyna Stanislawska; Norbert Wasik; Roman Jankowski; Włodzimierz Liebert
Journal:  Interv Neuroradiol       Date:  2015-05-11       Impact factor: 1.610

5.  Stent-assisted coil embolization of intracranial aneurysms using the Solitaire™ AB Neurovascular Remodeling Device: initial and midterm follow-up results.

Authors:  Christin Clajus; Vojtech Sychra; Christoph Strasilla; Joachim Klisch
Journal:  Neuroradiology       Date:  2013-02-06       Impact factor: 2.804

6.  Pointwise Encoding Time Reduction with Radial Acquisition with Subtraction-Based MRA during the Follow-Up of Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms.

Authors:  Y J Heo; H W Jeong; J W Baek; S T Kim; Y G Jeong; J Y Lee; S-C Jin
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-11       Impact factor: 3.825

Review 7.  Stent-supported aneurysm coiling: a literature survey of treatment and follow-up.

Authors:  M Shapiro; T Becske; D Sahlein; J Babb; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

8.  Disappearance of a small intracranial aneurysm as a result of vessel straightening and in-stent stenosis following use of an Enterprise vascular reconstruction device.

Authors:  Koichiro Takemoto; Satoshi Tateshima; Sachin Rastogi; Nestor Gonzalez; Reza Jahan; Gary Duckwiler; Fernando Vinuela
Journal:  BMJ Case Rep       Date:  2013-01-17

9.  Rescue stenting in endovascular treatment of acutely ruptured cerebral aneurysms.

Authors:  M Mahmoud
Journal:  Interv Neuroradiol       Date:  2013-03-04       Impact factor: 1.610

10.  Safety and efficacy of neuroform for treatment of intracranial aneurysms: a prospective, consecutive, French multicentric study.

Authors:  J C Gentric; A Biondi; M Piotin; C Mounayer; K Lobotesis; A Bonafé; V Costalat
Journal:  AJNR Am J Neuroradiol       Date:  2013-01-24       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.