Literature DB >> 16819677

Porous-coated cups fixed with screws: a 12-year clinical and radiostereometric follow-up study of 50 hips.

Stephan M Röhrl1, Bo Nivbrant, Finnur Snorrason, Johan Kärrholm, Kjell G Nilsson.   

Abstract

BACKGROUND: Excellent mid-term results have stimulated the use of hemispherical porous-coated cups in hip replacement. With longer follow-up, there have been problems related to polyethylene wear and liner fixation, and osteolysis has been documented in reports of selected cases. We evaluated the clinical and radiographic results of 50 patients followed for 12 years. PATIENTS AND METHODS: 58 consecutive patients (58 hips), mean age 55 years, were operated with Harris-Galante (HG) I or II cups using line-to-line fit and additional screw fixation. Polyethylene linersgamma-sterilized in air and 32-mm ceramic heads were used. 8 patients died within 12 years, leaving 50 patients with a complete 12 year follow-up. 23 of the cups were also evaluated with radiostereometry (RSA) for migration, liner stability, and wear.
RESULTS: All metal shells were still in situ after 12 years. 4 hips had been revised due to femoral loosening. In these revisions, the liner had been exchanged due to wear and/or instability, resulting in a cup survival rate of 89%. 28 cups displayed osteolytic lesions, mainly in relation to screws. RSA revealed minimum translations, but in many cases there were pronounced liner rotations suggesting unstable liners within the metal shell. The annual proximal wear was 0.09 mm and the three-dimensional wear was 0.16 mm.
INTERPRETATION: RSA can predict the long-term performance of cup fixation. Low migration during the initial years after implantation indicates excellent long-term results regarding fixation of the metal shell. The main problem with this design appears to be liner instability and osteolysis, factors that are probably interrelated. Because these phenomena are clinically silent, we recommend regular follow-up of patients with HG cups to avoid sudden loosening and complicated revisions.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16819677     DOI: 10.1080/17453670610046316

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  14 in total

1.  Acetabular screws do not improve early revision rates in primary total hip arthroplasty. An instrumented registry analysis.

Authors:  Mary Nugent; David G Campbell; Peter L Lewis; Alana R Cuthbert; Lucien B Solomon
Journal:  Int Orthop       Date:  2021-01-22       Impact factor: 3.075

2.  Second-generation modular acetabular components provide fixation at 10 to 16 years.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register.

Authors:  Nils P Hailer; Göran Garellick; Johan Kärrholm
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

4.  Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

5.  Effects of hydroxyapatite coating of cups used in hip revision arthroplasty.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2012-09-03       Impact factor: 3.717

6.  Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips.

Authors:  Thomas Baad-Hansen; Søren Kold; Poul Torben Nielsen; Mogens Berg Laursen; Poul Hedevang Christensen; Kjeld Soballe
Journal:  Acta Orthop       Date:  2011-03-25       Impact factor: 3.717

7.  No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups: an RSA study of 8 patients 10 yaers after surgery.

Authors:  Stephan M Röhrl; Bo Nivbrant; Kjell G Nilsson
Journal:  Acta Orthop       Date:  2012-01-17       Impact factor: 3.717

8.  Increased risk of revision of acetabular cups coated with hydroxyapatite.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

9.  A cementless, elastic press-fit socket with and without screws.

Authors:  Dean Pakvis; Joan Luites; Gijs van Hellemondt; Maarten Spruit
Journal:  Acta Orthop       Date:  2012-10       Impact factor: 3.717

10.  Preliminary analysis on the MD-4(®) plasma-sprayed titanium acetabular component.

Authors:  Elmano de Araújo Loures; Leandro Furtado Simoni; Isabel Cristina Gonçalves Leite; Daniel Naya Loures; Clarice Naya Loures
Journal:  Rev Bras Ortop       Date:  2015-03-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.