Literature DB >> 16816763

The effects of rod contouring on spinal construct fatigue strength.

Colleen Lindsey1, Vedat Deviren, Zheng Xu, Ru-Fang Yeh, Christian M Puttlitz.   

Abstract

STUDY
DESIGN: In vitro fatigue loading using a corpectomy model outfitted with posterior pedicle screw instrumentation.
OBJECTIVE: The purpose of this study was to detect differences in fatigue resistance of titanium and stainless steel spinal constructs that use rods contoured using a French Bender, and to compare differences in fatigue resistance of contoured and straight titanium rods. SUMMARY OF BACKGROUND DATA: Instrumentation failure is generally thought to be caused by fatigue or cyclic loading. Intraoperative contouring of the posterior rods is almost always required to match the native kyphotic (thoracic) or lordotic (cervical or lumbar) spinal curvature. How bending these rods affects their overall fatigue resistance is not well described. In addition, changes in fatigue resistance may be a function of material type.
METHODS: Spinal constructs were evaluated using the ASTM F1717-01 model. Two different titanium-based rods (Ti6AL4V and CpTi) and two different steel-based rods (Orthinox and 316L stainless steel) were evaluated in this study (n = 6 for each group). Rods were contoured at two points using a French Bender and were rigidly coupled to polyaxial pedicle screws within UHMWPE vertebral bodies. Constructs were cycled at a load ratio of 10 between a minimum and maximum loading regime of -250 N/-25 N and -700 N/-70 N at a frequency of 4 Hz. Estimated maximum nominal stresses at various points of interest in the spinal constructs were calculated using beam theory. Effects of the rod material, load, and stress on the number of cycles to failure were analyzed using Cox proportional hazards regression.
RESULTS: All of the spinal constructs with contoured CpTi rods and contoured Ti6Al4V rods failed at one of the bends in the rods. Almost all of the spinal constructs with straight CpTi rods and straight Ti6Al4V rods failed where the blocker screw fastens the rod to the coupler of the polyaxial screw head. Contoured titanium constructs demonstrated significantly lower fatigue life than contoured 316L constructs. Contouring tended to lower the fatigue life of both the Ti6Al4V and CpTi constructs.
CONCLUSION: Intraoperative rod contouring using a French Bender significantly reduces the fatigue life of titanium spinal constructs.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16816763     DOI: 10.1097/01.brs.0000224177.97846.00

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  17 in total

1.  The stabilizing potential of anterior, posterior and combined techniques for the reconstruction of a 2-level cervical corpectomy model: biomechanical study and first results of ATPS prototyping.

Authors:  Heiko Koller; Rene Schmidt; Michael Mayer; Wolfgang Hitzl; Juliane Zenner; Stefan Midderhoff; Stefan Middendorf; Nicolaus Graf; Nicolaus Gräf; H Resch; Hans-Joachim Wilke; Hans-Joachim Willke
Journal:  Eur Spine J       Date:  2010-06-30       Impact factor: 3.134

2.  Mechanical implant failure in posterior cervical spine fusion.

Authors:  Takeshi Okamoto; Masashi Neo; Shunsuke Fujibayashi; Hiromu Ito; Mitsuru Takemoto; Takashi Nakamura
Journal:  Eur Spine J       Date:  2011-10-16       Impact factor: 3.134

Review 3.  Current strategies for the restoration of adequate lordosis during lumbar fusion.

Authors:  Cédric Barrey; Alice Darnis
Journal:  World J Orthop       Date:  2015-01-18

Review 4.  Metallic Implants Used in Lumbar Interbody Fusion.

Authors:  Jakub Litak; Michał Szymoniuk; Wojciech Czyżewski; Zofia Hoffman; Joanna Litak; Leon Sakwa; Piotr Kamieniak
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

5.  Preliminary experience with SpineEOS, a new software for 3D planning in AIS surgery.

Authors:  Emmanuelle Ferrero; Keyvan Mazda; Anne-Laure Simon; Brice Ilharreborde
Journal:  Eur Spine J       Date:  2018-04-24       Impact factor: 3.134

6.  Designing patient-specific solutions using biomodelling and 3D-printing for revision lumbar spine surgery.

Authors:  Ganesha K Thayaparan; Mark G Owbridge; Robert G Thompson; Paul S D'Urso
Journal:  Eur Spine J       Date:  2018-07-10       Impact factor: 3.134

7.  Imaging appearances and clinical outcome following sacrectomy and ilio-lumbar reconstruction for sacral neoplasia.

Authors:  Marianna Thomas; A M Davies; A J Stirling; R J Grimer; M Grainger; Steven L J James
Journal:  Skeletal Radiol       Date:  2013-11-17       Impact factor: 2.199

8.  Biomechanical advantages of supplemental accessory and satellite rods with and without interbody cages implantation for the stabilization of pedicle subtraction osteotomy.

Authors:  Luigi La Barbera; Marco Brayda-Bruno; Christian Liebsch; Tomaso Villa; Andrea Luca; Fabio Galbusera; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2018-05-08       Impact factor: 3.134

9.  Utilization of Offset Iliac Connectors as Anchoring Sites in Severe Rigid Scoliosis: New Technique.

Authors:  Ahmed Barakat; Yasser El Mansy; Hesham El Saghir
Journal:  Global Spine J       Date:  2020-03-25

10.  Risk factors for rod fracture after posterior correction of adult spinal deformity with osteotomy: a retrospective case-series.

Authors:  Cameron Barton; Andriy Noshchenko; Vikas Patel; Christopher Cain; Christopher Kleck; Evalina Burger
Journal:  Scoliosis       Date:  2015-11-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.