Literature DB >> 16816433

The use of percutaneous suture-mediated closure for the management of 14 French femoral venous access.

Ilias Mylonas1, Yoshihito Sakata, Michael Salinger, Timothy A Sanborn, Ted Feldman.   

Abstract

BACKGROUND: Little has been reported regarding the utility or outcomes of femoral venous vascular closure using arterial suture closure devices. We describe results using a pre-closure approach with a 6 French (Fr) Perclose Closer S device in patients who underwent antegrade aortic valvuloplasty using 14 Fr percutaneous femoral venous access catheters.
METHODS: Forty-five patients underwent antegrade aortic valvuloplasty and suture-mediated closure with a 6 Fr Perclose device. A 6 Fr Closer S suture device was preloaded into the femoral vein after 6 Fr sheath access, prior to insertion of a 14 Fr venous sheath. Upon completion of the procedure, the 14 Fr femoral venous sheath was removed through the existing sutures.
RESULTS: Of 45 patients (mean age 82.4 years; 17 males), immediate hemostasis was achieved with percutaneous suture closure in 43 (95.6%). Only 2 failures occurred which were subsequently successfully treated with manual compression. No late access site bleeding occurred from sutured sites. In all other patients, hemostasis using a 6 Fr Perclose suture-mediated device was successful and immediate. There was no need for transfusion, no clinical venous thrombosis, and no infections occurred at the access site. Two hospital deaths were documented from causes unrelated to suture-mediated closure.
CONCLUSIONS: In conjunction with 14-Fr size percutaneous sheaths during antegrade aortic valvuloplasty, percutaneous suturemediated closure is a highly effective method for achieving hemostasis. This has simplified postprocedural management in terms of early mobilization and diminished late access site bleeding.

Entities:  

Mesh:

Year:  2006        PMID: 16816433

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  4 in total

1.  Use of vascular closure device is safe and effective in electrophysiological procedures.

Authors:  Ilir Maraj; Adam S Budzikowski; Waleed Ali; Crisitina A Mitre; John Kassotis
Journal:  J Interv Card Electrophysiol       Date:  2015-04-29       Impact factor: 1.900

2.  Venous hemostasis postcatheter ablation of atrial fibrillation while under therapeutic levels of oral and intravenous anticoagulation.

Authors:  Ziad F Issa; Bashar S Amr
Journal:  J Interv Card Electrophysiol       Date:  2015-07-30       Impact factor: 1.900

3.  Pre-closure of Large-Sized Arterial Access Sites in Adults Undergoing Transcatheter Structural Interventions.

Authors:  Tahir Hamid; Tawfiq R Choudhury; Bernard Clarke; Vaikom S Mahadevan
Journal:  Cardiol Ther       Date:  2014-12-23

4.  Feasibility of the Figure-of-8-Suture as Venous Closure in Interventional Electrophysiology: One Strategy for All?

Authors:  Christoph J Jensen; Miriam Schnur; Sebastian Lask; Philipp Attanasio; Michal Gotzmann; Kaffer Kara; Christoph Hanefeld; Andreas Mügge; Alexander Wutzler
Journal:  Int J Med Sci       Date:  2020-04-06       Impact factor: 3.738

  4 in total