Literature DB >> 16808078

The predictive power of surface profile parameters on the amount of wear measured in vitro on metal-on-polyethylene artificial hip joints.

S Affatato1, G Bersaglia, Yin Junqiang, F Traina, A Toni, M Viceconti.   

Abstract

Various studies report a weak correlation between the average surface roughness R(a) of metallic ballheads and the observed wear rate of the polyethylene cups coupled to them. The aim of this study is to verify, with controlled in vitro experiments, whether other parameters such as the total roughness R(t), and the skewness R(sk) are better predictors of the polyethylene wear when the metallic heads present a surface conditioning that varies substantially from specimen to specimen, as is usually the case with retrieved specimens. Twelve CoCrMo (cobalt-chromium-molybdenum) ballheads were intentionally damaged in order to reproduce a wide spectrum of surface conditioning and were then subjected to the standard wear test against polyethylene cups, using a hip joint wear simulator. After 2 x 10(6) cycles the weight lost by the cups was assessed with a gravimetric procedure, and the surface roughness of the metallic ballheads was qualified in terms of R(a), R(t), and R(sk). The various parameters were correlated to the weight loss using a linear regression analysis. The skewness R(sk) showed a coefficient linear regression R2 = 0.80, while the average roughness R(a), used in most previous studies, presented an R2 = 0.56. It was concluded that when specimens with substantially different surface conditioning are compared, as in retrievals analysis, it is also important to report the skewness R(sk) so that qualify the surface roughness of the specimens can be qualified.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16808078     DOI: 10.1243/09544119JEIM95

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  4 in total

1.  Toward the interpretation of the combined effect of size and body weight on the tribological performance of total knee prostheses.

Authors:  Santina Battaglia; Paola Taddei; Silvia Tozzi; Alessandra Sudanese; Saverio Affatato
Journal:  Int Orthop       Date:  2014-02-26       Impact factor: 3.075

2.  Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.

Authors:  Marcel E Roy; Leo A Whiteside; Mark E Magill; Brian J Katerberg
Journal:  Clin Orthop Relat Res       Date:  2011-02-11       Impact factor: 4.176

3.  Oxidized zirconium versus cobalt-chromium in TKA: profilometry of retrieved femoral components.

Authors:  Thomas J Heyse; Marcella E Elpers; Danyal H Nawabi; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

4.  Wear Simulation of Ceramic-on-Crosslinked Polyethylene Hip Prostheses: A New Non-Oxide Silicon Nitride versus the Gold Standard Composite Oxide Ceramic Femoral Heads.

Authors:  Makiko Yorifuji; Saverio Affatato; Toshiyuki Tateiwa; Yasuhito Takahashi; Takaaki Shishido; Elia Marin; Matteo Zanocco; Wenliang Zhu; Giuseppe Pezzotti; Kengo Yamamoto
Journal:  Materials (Basel)       Date:  2020-06-29       Impact factor: 3.623

  4 in total