Literature DB >> 16803648

Postanaesthetic tracheal strictures in three rabbits.

N J Grint1, I R Sayers, R Cecchi, R Harley, M J Day.   

Abstract

Within an 11-day period, three rabbits were anaesthetized for neutering. All were endotracheally intubated with 12 cm long, 2.5 mm (inner diameter [ID]) polyvinylchloride (PVC) tubes. All rabbits developed clinical signs of dyspnoea and upper respiratory tract obstruction, 17-21 days later. One rabbit was found dead; the other two were treated, but one was euthanized and one died. At necropsy examination, focal chronic inflammation and significant localized narrowing of the tracheal lumen was found in all cases. The affected sites corresponded to the position of the bevel of the endotracheal tube (ETT) during anaesthesia. Histopathology could not differentiate between a traumatic or chemical cause for the narrowing. Possible causes include trauma by the bevel of the ETT when turning the rabbit or preparing the surgical site or a chemical burn from incorrect disinfection or inadequate rinsing of the tubes. Iatrogenic tracheitis should be considered as a cause of dyspnoea, when clinical signs arise 2-3 weeks after anaesthesia.

Entities:  

Mesh:

Year:  2006        PMID: 16803648     DOI: 10.1258/002367706777611415

Source DB:  PubMed          Journal:  Lab Anim        ISSN: 0023-6772            Impact factor:   2.471


  5 in total

1.  Capnography-guided Endotracheal Intubation as an Alternative to Existing Intubation Methods in Rabbits.

Authors:  Lyon Y Lee; Dongbin Lee; Hakhyun Ryu; Janet H Han; Jungho Ko; John W Tyler
Journal:  J Am Assoc Lab Anim Sci       Date:  2019-01-09       Impact factor: 1.232

2.  Description of a Recovery Model in Rabbits for the Study of the Late Phase of Liver Ischemia-Reperfusion Injury.

Authors:  Athina G Mantelou; Argyro Zacharioudaki; George Pappas-Gogos; Apostolos Papalois; Alexandra Papoudou-Bai; Anna Goussia; Georgios K Glantzounis
Journal:  In Vivo       Date:  2022 Jan-Feb       Impact factor: 2.155

3.  Successful management of rabbit anesthesia through the use of nasotracheal intubation.

Authors:  Julie M Stephens Devalle
Journal:  J Am Assoc Lab Anim Sci       Date:  2009-03       Impact factor: 1.232

4.  Comparison of a Supraglottic Airway Device (v-gel®) with Blind Orotracheal Intubation in Rabbits.

Authors:  Sarah Engbers; Amy Larkin; Nicolas Rousset; Melanie Prebble; Mahesh Jonnalagadda; Cameron G Knight; Daniel S J Pang
Journal:  Front Vet Sci       Date:  2017-04-10

5.  Endotracheal Intubation of Rabbits Using a Polypropylene Guide Catheter.

Authors:  Krista L Thompson; Thomas R Meier; Jodi A Scholz
Journal:  J Vis Exp       Date:  2017-11-13       Impact factor: 1.355

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.