Microvascular behavior and effects of sonazoid microbubbles in the cremaster muscle of rats after local administration.

Magnus Braide1, Henrik Rasmussen, Ann Albrektsson, Ulf Bagge.   

Abstract

OBJECTIVE: The purpose of this study was to observe Sonazoid perfluorobutane microbubbles (GE Healthcare, Amersham, Buckinghamshire, England) in and their effects on the cremaster capillary microcirculation of rats.
METHODS: Sonazoid (0.3 x 10(9) microbubbles in 0.5 mL) was observed by intravital microscopy in the cremaster muscle after retrograde administration into the femoral artery of 6 animals. Microbubble and microvessel diameters and blood flow velocities and the overall mean and SD of the 1-minute volume flow through the microscopic field were calculated from the 2 to 4 capillaries observed in the field of each animal. Fluorescein isothiocyanate-dextran leakage was used to assess extravasation after microbubble passage.
RESULTS: seconds, respectively, before they were released and capillary flow normalized. No microbubble size changes, damming, or coalescence of bubbles and no changes in microvessel diameter or microvascular blood flow velocities, volume flow, or perfusion heterogeneity occurred during or after the passage of the Sonazoid suspension or the vehicle. No fluorescein isothiocyanate-dextran leakage was observed.
CONCLUSIONS: The passage of Sonazoid bubbles at concentrations higher than those expected after intravenous administration of the Sonazoid did not durably impair microvascular perfusion, structural integrity, or macromolecular retention in the rat cremaster muscle. The duration of discrete capillary obstructions was short and in all cases comparable with that of naturally occurring leukocyte plugging.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16798899     DOI: 10.7863/jum.2006.25.7.883

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  5 in total

1.  Magnetic stents retain nanoparticle-bound antirestenotic drugs transported by lipid microbubbles.

Authors:  T Räthel; H Mannell; J Pircher; B Gleich; U Pohl; F Krötz
Journal:  Pharm Res       Date:  2011-12-22       Impact factor: 4.200

2.  An ex vivo study of the correlation between acoustic emission and microvascular damage.

Authors:  Stanley Samuel; Michol A Cooper; Joseph L Bull; J Brian Fowlkes; Douglas L Miller
Journal:  Ultrasound Med Biol       Date:  2009-06-27       Impact factor: 2.998

3.  Association of Contrast-Enhanced Ultrasound-Derived Kidney Cortical Microvascular Perfusion with Kidney Function.

Authors:  Anand Srivastava; Anush Sridharan; Rachel W Walmer; Sandeep K Kasoji; Lauren M B Burke; Paul A Dayton; Kennita A Johnson; Emily H Chang
Journal:  Kidney360       Date:  2022-01-26

Review 4.  Bench-to-bedside review: contrast enhanced ultrasonography--a promising technique to assess renal perfusion in the ICU.

Authors:  Antoine Schneider; Lynne Johnson; Mark Goodwin; Anthony Schelleman; Rinaldo Bellomo
Journal:  Crit Care       Date:  2011-05-06       Impact factor: 9.097

5.  Monitoring of Blood Vessel Density Using Contrast-Enhanced High Frequency Ultrasound May Facilitate Early Diagnosis of Lymph Node Metastasis.

Authors:  Takuma Sato; Tomoaki Takemura; Tomoki Ouchi; Shiro Mori; Maya Sakamoto; Yoichi Arai; Tetsuya Kodama
Journal:  J Cancer       Date:  2017-02-25       Impact factor: 4.207