Literature DB >> 16798418

Impact of geometrical uncertainties on 3D CRT and IMRT dose distributions for lung cancer treatment.

Marco Schwarz1, Joris Van der Geer, Marcel Van Herk, Joos V Lebesque, Ben J Mijnheer, Eugène M F Damen.   

Abstract

PURPOSE: To quantify the effect of set-up errors and respiratory motion on dose distributions for non-small cell lung cancer (NSCLC) treatment. METHODS AND MATERIALS: Irradiations of 5 NSCLC patients were planned with 3 techniques, two (conformal radiation therapy (CRT) and intensity modulated radiation therapy (IMRT1)) with a homogeneous dose in the planning target volume (PTV) and a third (IMRT2) with dose heterogeneity. Set-up errors were simulated for gross target volume (GTV) and organs at risk (OARs). For the GTV, the respiration was also simulated with a periodical motion around a varying average. Two configurations were studied for the breathing motion, to describe the situations of free-breathing (FB) and respiration-correlated (RC) CT scans, each with 2 amplitudes (5 and 10 mm), thus resulting in 4 scenarios (FB_5, FB_10, RC_5 and RC_10). Five thousand treatment courses were simulated, producing probability distributions for the dosimetric parameters.
RESULTS: For CRT and IMRT1, RC_5, RC_10 and FB_5 were associated with a small degradation of the GTV coverage. IMRT2 with FB_10 showed the largest deterioration of the GTV dosimetric indices, reaching 7% for Dmin at the 95% probability level. Removing the systematic error due to the periodic breathing motion was advantageous for a 10 mm respiration amplitude. The estimated probability of radiation pneumonitis and acute complication for the esophagus showed limited sensitivity to geometrical uncertainties. Dmax in the spinal cord and the parameters predicting the risk of late esophageal toxicity were associated to a probability up to 50% of violating the dose tolerances.
CONCLUSIONS: Simulating the effect of geometrical uncertainties on the individual patient plan should become part of the standard pre-treatment verification procedure.

Entities:  

Mesh:

Year:  2006        PMID: 16798418     DOI: 10.1016/j.ijrobp.2006.03.035

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  21 in total

1.  The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery.

Authors:  Marianne Falk; Tobias Larsson; Paul Keall; Byung Chul Cho; Marianne Aznar; Stine Korreman; Per Poulsen; Per Munck Af Rosenschold
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  Inverse 4D conformal planning for lung SBRT using particle swarm optimization.

Authors:  A Modiri; X Gu; A Hagan; R Bland; P Iyengar; R Timmerman; A Sawant
Journal:  Phys Med Biol       Date:  2016-08-01       Impact factor: 3.609

3.  Inversed-Planned Respiratory Phase Gating in Lung Conformal Radiation Therapy.

Authors:  Arezoo Modiri; Pouya Sabouri; Xuejun Gu; Robert Timmerman; Amit Sawant
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-06-01       Impact factor: 7.038

Review 4.  Improving radiation conformality in the treatment of non-small cell lung cancer.

Authors:  Joe Y Chang; James D Cox
Journal:  Semin Radiat Oncol       Date:  2010-07       Impact factor: 5.934

5.  Intensity-Modulated Radiation Therapy May Improve Local-Regional Tumor Control for Locally Advanced Non-Small Cell Lung Cancer Compared With Three-Dimensional Conformal Radiation Therapy.

Authors:  Jingbo Wang; Zongmei Zhou; Jun Liang; Qinfu Feng; Zefen Xiao; Zhouguang Hui; Xiaozhen Wang; Jima Lv; Dongfu Chen; Hongxing Zhang; Zhe Ji; Jianzhong Cao; Lipin Liu; Wei Jiang; Yu Men; Cai Xu; Jiangrong Dai; Weibo Yin; Luhua Wang
Journal:  Oncologist       Date:  2016-09-14

6.  Short-term displacement and reproducibility of the breast and nodal targets under active breathing control.

Authors:  Jean M Moran; James M Balter; Merav A Ben-David; Robin B Marsh; Marcel Van Herk; Lori J Pierce
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-06-01       Impact factor: 7.038

7.  Evaluation of multiple breathing states using a multiple instance geometry approximation (MIGA) in inverse-planned optimization for locoregional breast treatment.

Authors:  Alexander Lin; Jean M Moran; Robin B Marsh; James M Balter; Benedick A Fraass; Daniel L McShan; Marc L Kessler; Lori J Pierce
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-10-01       Impact factor: 7.038

8.  Comparison of Toxicity Between Intensity-Modulated Radiotherapy and 3-Dimensional Conformal Radiotherapy for Locally Advanced Non-small-cell Lung Cancer.

Authors:  Diane C Ling; Clayton B Hess; Allen M Chen; Megan E Daly
Journal:  Clin Lung Cancer       Date:  2015-08-03       Impact factor: 4.785

9.  Clinical Application of a Hybrid RapidArc Radiotherapy Technique for Locally Advanced Lung Cancer.

Authors:  Scott R Silva; Murat Surucu; Jennifer Steber; Matthew M Harkenrider; Mehee Choi
Journal:  Technol Cancer Res Treat       Date:  2016-09-28

10.  Four-dimensional planning for motion synchronized dose delivery in lung stereotactic body radiation therapy.

Authors:  Hidenobu Tachibana; Amit Sawant
Journal:  Radiother Oncol       Date:  2016-04-30       Impact factor: 6.280

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.