Literature DB >> 16794178

Postmortem radiology of fatal hemorrhage: measurements of cross-sectional areas of major blood vessels and volumes of aorta and spleen on MDCT and volumes of heart chambers on MRI.

Emin Aghayev1, Martin Sonnenschein, Christian Jackowski, Michael Thali, Ursula Buck, Kathrin Yen, Stephan Bolliger, Richard Dirnhofer, Peter Vock.   

Abstract

OBJECTIVE: Autopsy determination of fatal hemorrhage as the cause of death is often a difficult diagnosis in forensic medicine. No quantitative system for accurately measuring the blood volume in a corpse has been developed.
MATERIALS AND METHODS: This article describes the measurement and evaluation of the cross-sectional areas of major blood vessels, of the diameter of the right pulmonary artery, of the volumes of thoracic aorta and spleen on MDCT, and of the volumes of heart chambers on MRI in 65 autopsy-verified cases of fatal hemorrhage or no fatal hemorrhage.
RESULTS: Most cases with a cause of death of "fatal hemorrhage" had collapsed vessels. The finding of a collapsed superior vena cava, main pulmonary artery, or right pulmonary artery was 100% specific for fatal hemorrhage. The mean volumes of the thoracic aorta and of each of the heart chambers and the mean cross-sectional areas of all vessels except the inferior vena cava and abdominal aorta were significantly smaller in fatal hemorrhage than in no fatal hemorrhage.
CONCLUSION: For the quantitative differentiation of fatal hemorrhage from other causes of death, we propose a three-step algorithm with measurements of the diameter of the right pulmonary artery, the cross-sectional area of the main pulmonary artery, and the volume of the right atrium (specificity, 100%; sensitivity, 95%). However, this algorithm must be corroborated in a prospective study, which would eliminate the limitations of this study. Quantitative postmortem cross-sectional imaging might become a reliable objective method to assess the question of fatal hemorrhage in forensic medicine.

Entities:  

Mesh:

Year:  2006        PMID: 16794178     DOI: 10.2214/AJR.05.0222

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  17 in total

Review 1.  Virtual autopsy using imaging: bridging radiologic and forensic sciences. A review of the Virtopsy and similar projects.

Authors:  Stephan A Bolliger; Michael J Thali; Steffen Ross; Ursula Buck; Silvio Naether; Peter Vock
Journal:  Eur Radiol       Date:  2007-08-18       Impact factor: 5.315

Review 2.  Advances in post-mortem CT-angiography.

Authors:  S Grabherr; J Grimm; A Dominguez; J Vanhaebost; P Mangin
Journal:  Br J Radiol       Date:  2014-04       Impact factor: 3.039

3.  Intrahepatic gas at postmortem multislice computed tomography in cases of nontraumatic death.

Authors:  Naoya Takahashi; Takeshi Higuchi; Motoi Shiotani; Haruo Maeda; Yasuo Hirose
Journal:  Jpn J Radiol       Date:  2009-08-28       Impact factor: 2.374

4.  Current status of routine post-mortem CT in Melbourne, Australia.

Authors:  C O'Donnell; A Rotman; S Collett; N Woodford
Journal:  Forensic Sci Med Pathol       Date:  2007-10-10       Impact factor: 2.007

5.  Postmortem MR quantification of the heart for characterization and differentiation of ischaemic myocardial lesions.

Authors:  Wolf-Dieter Zech; Nicole Schwendener; Anders Persson; Marcel J Warntjes; Christian Jackowski
Journal:  Eur Radiol       Date:  2015-01-16       Impact factor: 5.315

6.  Temperature dependence of postmortem MR quantification for soft tissue discrimination.

Authors:  Wolf-Dieter Zech; Nicole Schwendener; Anders Persson; Marcel J Warntjes; Christian Jackowski
Journal:  Eur Radiol       Date:  2015-02-01       Impact factor: 5.315

7.  Postmortem quantitative 1.5-T MRI for the differentiation and characterization of serous fluids, blood, CSF, and putrefied CSF.

Authors:  Wolf-Dieter Zech; Nicole Schwendener; Anders Persson; Marcel J Warntjes; Fabiano Riva; Frederick Schuster; Christian Jackowski
Journal:  Int J Legal Med       Date:  2015-07-11       Impact factor: 2.686

8.  The role of angiography in the congruence of cardiovascular measurements between autopsy and postmortem imaging.

Authors:  Renaud Troxler; Costin Minoiu; Paul Vaucher; Katarzyna Michaud; Francesco Doenz; Kewin Ducrot; Silke Grabherr
Journal:  Int J Legal Med       Date:  2017-07-24       Impact factor: 2.686

9.  Vascular measurement changes observed using postmortem computed tomography.

Authors:  Hideki Hyodoh; Taishi Sato; Maki Onodera; Hirokazu Washio; Tadashi Hasegawa; Masamitsu Hatakenaka
Journal:  Jpn J Radiol       Date:  2012-10-03       Impact factor: 2.374

10.  Postmortem computed tomography findings as evidence of traffic accident-related fatal injury.

Authors:  Seiji Shiotani; Masanari Shiigai; Yukihiro Ueno; Namiko Sakamoto; Shigeru Atake; Mototsugu Kohno; Masatsune Suzuki; Hiroshi Kimura; Kazunori Kikuchi; Hideyuki Hayakawa
Journal:  Radiat Med       Date:  2008-07-27
View more