Literature DB >> 16791860

Decomposed direct matrix inversion for fast non-cartesian SENSE reconstructions.

Yongxian Qian1, Zhenghui Zhang, Yi Wang, Fernando E Boada.   

Abstract

A new k-space direct matrix inversion (DMI) method is proposed here to accelerate non-Cartesian SENSE reconstructions. In this method a global k-space matrix equation is established on basic MRI principles, and the inverse of the global encoding matrix is found from a set of local matrix equations by taking advantage of the small extension of k-space coil maps. The DMI algorithm's efficiency is achieved by reloading the precalculated global inverse when the coil maps and trajectories remain unchanged, such as in dynamic studies. Phantom and human subject experiments were performed on a 1.5T scanner with a standard four-channel phased-array cardiac coil. Interleaved spiral trajectories were used to collect fully sampled and undersampled 3D raw data. The equivalence of the global k-space matrix equation to its image-space version, was verified via conjugate gradient (CG) iterative algorithms on a 2x undersampled phantom and numerical-model data sets. When applied to the 2x undersampled phantom and human-subject raw data, the decomposed DMI method produced images with small errors (< or = 3.9%) relative to the reference images obtained from the fully-sampled data, at a rate of 2 s per slice (excluding 4 min for precalculating the global inverse at an image size of 256 x 256). The DMI method may be useful for noise evaluations in parallel coil designs, dynamic MRI, and 3D sodium MRI with fixed coils and trajectories. Copyright 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16791860     DOI: 10.1002/mrm.20974

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Improved self-calibrated spiral parallel imaging using JSENSE.

Authors:  Jinhua Sheng; Erik Wiener; Bo Liu; Fernando Boada; Leslie Ying
Journal:  Med Eng Phys       Date:  2008-11-21       Impact factor: 2.242

Review 2.  Quantitative sodium MR imaging: A review of its evolving role in medicine.

Authors:  Keith R Thulborn
Journal:  Neuroimage       Date:  2016-11-24       Impact factor: 6.556

3.  Variable-density parallel imaging with partially localized coil sensitivities.

Authors:  Tolga Cukur; Juan M Santos; John M Pauly; Dwight G Nishimura
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.