The spectrum and the polarization of the magnetic flux density (B-field) of 6 induction heaters and 1 arc oven were measured by means of a PMM (Italy) spectrum analyser. The spectrum analysis showed that no substantial harmonics were observed while the polarization analysis revealed that the operator's exposure was non-homogeneous within a distance of 1.5 m from the heater. When the distance was larger, the body was homogeneously exposed. In general we can state that the B-field strongly varied between heaters and that exposure exceeded the occupational reference levels recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) (1998) and European Directive 2004/40/EC in 5 of the 7 heaters. Within the framework of the Directive some protection actions should be taken. Whereas mitigation of existing/old induction ovens is difficult, the design of new induction heaters and their housing should be based, among others, on electromagnetic reducing engineering concepts.

Entities:  

Mesh:

Year:  2006        PMID: 16790174     DOI: 10.1080/10803548.2006.11076678

Source DB:  PubMed          Journal:  Int J Occup Saf Ergon        ISSN: 1080-3548


  6 in total

Review 1.  The revised electromagnetic fields directive and worker exposure in environments with high magnetic flux densities.

Authors:  Rianne Stam
Journal:  Ann Occup Hyg       Date:  2014-02-20

2.  Lack of teratological effects in rats exposed to 20 or 60 kHz magnetic fields.

Authors:  Izumi Nishimura; Atsushi Oshima; Kazumoto Shibuya; Tadashi Negishi
Journal:  Birth Defects Res B Dev Reprod Toxicol       Date:  2011-07-18

3.  Acute and subchronic toxicity of 20  kHz and 60  kHz magnetic fields in rats.

Authors:  Izumi Nishimura; Atsushi Oshima; Kazumoto Shibuya; Takashi Mitani; Tadashi Negishi
Journal:  J Appl Toxicol       Date:  2015-05-17       Impact factor: 3.446

4.  Early exposure to intermediate-frequency magnetic fields alters brain biomarkers without histopathological changes in adult mice.

Authors:  Tin-Tin Win-Shwe; Shin Ohtani; Akira Ushiyama; Naoki Kunugita
Journal:  Int J Environ Res Public Health       Date:  2015-04-22       Impact factor: 3.390

5.  Influence and Correction from the Human Body on the Measurement of a Power-Frequency Electric Field Sensor.

Authors:  Dongping Xiao; Huaitong Liu; Qiang Zhou; Yutong Xie; Qichao Ma
Journal:  Sensors (Basel)       Date:  2016-06-10       Impact factor: 3.576

6.  A Power-Frequency Electric Field Sensor for Portable Measurement.

Authors:  Dongping Xiao; Qichao Ma; Yutong Xie; Qi Zheng; Zhanlong Zhang
Journal:  Sensors (Basel)       Date:  2018-03-31       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.